FHWA NBI 2024 Inspection record Public-domain dataset

US 30 W.B.; SR0030

Carrying US 30 W.B.; SR0030 over US 222 SB & NB

US 30 WB OVER PA272/US222, Lancaster, Pennsylvania

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
54 t Inventory load rating Higher than 90% of rated Pennsylvania bridges

US 30 W.B.; SR0030 in Lancaster, Pennsylvania sits above 90% of rated Pennsylvania bridges on inventory load rating (54 t), while its 2001 build year is earlier than 21% of Lancaster's recorded-year cohort (801 bridges).

US 30 W.B.; SR0030 in Lancaster, Pennsylvania is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 2001, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure PA:000000000041281

POST-2000 · PRESTRESS · MULTI-SPAN · TIED-CTRL · HEAVY-ADT · HEAVY-LOAD · CAT-GOOD

  • POST-2000 2000+
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 2 spans
  • TIED-CTRL Tied control
  • HEAVY-ADT Heavy ADT
  • HEAVY-LOAD Heavy load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: US 30 W.B.; SR0030

The US 30 W.B.; SR0030 bridge in Lancaster, Pennsylvania carries US 30 W.B.; SR0030 over US 222 SB & NB. It was built in 2001, making it 25 years old today. The structure is built primarily of prestressed concrete continuous and spans 2 sections, stretching 44.5 meters (146 feet) end to end. Daily traffic averages 67,734 vehicles, placing it in the heavily-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range.

How US 30 W.B.; SR0030 compares

▲ 16.0
Load rating vs Pennsylvania average (38.4 t; 23,297 of 23,299 rated)
801
Bridges in Lancaster · 90 in Poor condition

Age against the county: built in 2001, earlier than 168 of Lancaster's 801 bridges with a recorded construction year (21%), against a county median build year of 1972. This is one of the newer structures in its county.

US 30 W.B.; SR0030 54.4 t
Pennsylvania average (23,297 of 23,299 rated) 38.4 t

Live comparison across Pennsylvania bridges with a recorded inventory load rating (23,297 of 23,299 rated).

US 30 W.B.; SR0030 vs every rated Pennsylvania bridge

Inventory load rating (metric tons), FHWA NBI, this state

54 Top 10% higher than 90% of 23,297 bridges

rated Pennsylvania bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
54.4 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Lancaster inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 801 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
2001
Material
Prestressed Concrete Continuous
Number of Spans
2
Structure Length
44.5 m (146 ft)
Deck Width
18.8 m (62 ft)
Owner
State Highway Agency
Avg Daily Traffic
67,734 vehicles/day
Structure Number
000000000041281

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether US 30 W.B.; SR0030 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare US 30 W.B.; SR0030 against other structures in Lancaster and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for US 30 W.B.; SR0030?

US 30 W.B.; SR0030 in Lancaster, Pennsylvania has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is US 30 W.B.; SR0030 inspected?

US 30 W.B.; SR0030's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 67,734 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. US 30 W.B.; SR0030 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for US 30 W.B.; SR0030?

US 30 W.B.; SR0030 has an NBI inventory load rating of 54.4 metric tons.

Who is responsible for maintaining US 30 W.B.; SR0030?

US 30 W.B.; SR0030 is owned and maintained by State Highway Agency.

How old is US 30 W.B.; SR0030 and does age affect safety?

US 30 W.B.; SR0030 was built in 2001, making it 25 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.