FHWA NBI 2024 Inspection record Public-domain dataset

T-309 HARTLEY TWP

Carrying T-309 HARTLEY TWP over PENNS CREEK

LAUREL PARK, Union, Pennsylvania

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
35 t Inventory load rating Lower than 57% of rated Pennsylvania bridges

T-309 HARTLEY TWP in Union, Pennsylvania sits above 43% of rated Pennsylvania bridges on inventory load rating (35 t), while its 2018 build year is earlier than 5% of Union's recorded-year cohort (163 bridges).

T-309 HARTLEY TWP in Union, Pennsylvania is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 2018, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 8. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure PA:000000000055737

POST-2000 · PRESTRESS · MULTI-SPAN · SUB-LED · LOCAL-ADT · STANDARD-LOAD · CAT-GOOD

  • POST-2000 2000+
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 3 spans
  • SUB-LED Substructure-led
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: T-309 HARTLEY TWP

The T-309 HARTLEY TWP bridge in Union, Pennsylvania carries T-309 HARTLEY TWP over PENNS CREEK. It was built in 2018, making it 8 years old today. The structure is built primarily of prestressed concrete continuous and spans 3 sections, stretching 64.6 meters (212 feet) end to end. Daily traffic averages 148 vehicles, placing it in the lower-traffic tier of Pennsylvania bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 9/9, superstructure at 9/9, substructure at 8/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How T-309 HARTLEY TWP compares

▼ 3.1
Load rating vs Pennsylvania average (38.4 t; 23,297 of 23,299 rated)
163
Bridges in Union · 7 in Poor condition

Age against the county: built in 2018, earlier than 8 of Union's 163 bridges with a recorded construction year (5%), against a county median build year of 1970. This is one of the newer structures in its county.

T-309 HARTLEY TWP 35.3 t
Pennsylvania average (23,297 of 23,299 rated) 38.4 t

Live comparison across Pennsylvania bridges with a recorded inventory load rating (23,297 of 23,299 rated).

T-309 HARTLEY TWP vs every rated Pennsylvania bridge

Inventory load rating (metric tons), FHWA NBI, this state

35 Top 57% higher than 43% of 23,297 bridges

rated Pennsylvania bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
9/9
Good (7–9)
Superstructure
9/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
35.3 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Union inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 163 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
2018
Material
Prestressed Concrete Continuous
Number of Spans
3
Structure Length
64.6 m (212 ft)
Deck Width
8.4 m (28 ft)
Owner
County Highway Agency
Avg Daily Traffic
148 vehicles/day
Structure Number
000000000055737

Condition Analysis

  • The deck (driving surface) rates good at 9/9, with no significant deterioration on file.
  • At 9/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates good at 8/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether T-309 HARTLEY TWP is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare T-309 HARTLEY TWP against other structures in Union and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for T-309 HARTLEY TWP?

T-309 HARTLEY TWP in Union, Pennsylvania has a deck rating of 9/9, superstructure rating of 9/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is T-309 HARTLEY TWP inspected?

T-309 HARTLEY TWP's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 148 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. T-309 HARTLEY TWP is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for T-309 HARTLEY TWP?

T-309 HARTLEY TWP has an NBI inventory load rating of 35.3 metric tons.

Who is responsible for maintaining T-309 HARTLEY TWP?

T-309 HARTLEY TWP is owned and maintained by County Highway Agency.

How old is T-309 HARTLEY TWP and does age affect safety?

T-309 HARTLEY TWP was built in 2018, making it 8 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.