OFF PR 200
Carrying OFF PR 200 over CREEK
ISABEL II CITY VIEQUES, Vieques, Puerto Rico
Inventory: FHWA NBI 2024 · last ETL August 2026
FHWA NBI record, refreshed with each annual release.
OFF PR 200 in Vieques, Puerto Rico sits above 2% of rated Puerto Rico bridges on inventory load rating (3 t), while its 1930 build year is earlier than 85% of Vieques's recorded-year cohort (13 bridges).
OFF PR 200 in Vieques, Puerto Rico is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1930, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 2. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.
NBI record plate
Structure PR:011331
PRE-1950 · CONCRETE · MULTI-SPAN · SUPER-LED · LOCAL-ADT · LIGHT-LOAD · CAT-POOR
- PRE-1950 Pre-1950
- CONCRETE Concrete
- MULTI-SPAN 2 spans
- SUPER-LED Superstructure-led
- LOCAL-ADT Local ADT
- LIGHT-LOAD Light load
- CAT-POOR Poor
Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.
Structural health score
A composite of the deck, superstructure, and substructure NBI condition ratings plus the inventory load rating, benchmarked against the full national bridge corpus, distinct from the Good/Fair/Poor category above.
Bridge Snapshot: OFF PR 200
The OFF PR 200 bridge in Vieques, Puerto Rico carries OFF PR 200 over CREEK. It was built in 1930, making it 96 years old today. The structure is built primarily of concrete continuous and spans 2 sections, stretching 14.0 meters (46 feet) end to end. Daily traffic averages 500 vehicles, placing it in the lower-traffic tier of Puerto Rico bridges. It is owned and maintained by City/Municipal Highway Agency.
The latest FHWA inspection places the weakest component in critical condition (see the full component ratings below). At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules.
How OFF PR 200 compares
Age against the county: built in 1930, earlier than 11 of Vieques's 13 bridges with a recorded construction year (85%), against a county median build year of 2009. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.
Live comparison across Puerto Rico bridges with a recorded inventory load rating (2,385 rated).
OFF PR 200 vs every rated Puerto Rico bridge
Inventory load rating (metric tons), FHWA NBI, this state
3 Top 98% higher than 2% of 2,385 bridges
rated Puerto Rico bridges, bucketed by value
Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.
Source FHWA National Bridge Inventory · August 2026
Condition Ratings
Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.
Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.
Vieques inventory by recorded NBI category
Exclusive Good/Fair/Poor bands across all 13 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.
Structural Details
- Year Built
- 1930
- Material
- Concrete Continuous
- Number of Spans
- 2
- Structure Length
- 14.0 m (46 ft)
- Deck Width
- 4.8 m (16 ft)
- Owner
- City/Municipal Highway Agency
- Avg Daily Traffic
- 500 vehicles/day
- Structure Number
- 011331
Condition Analysis
- • At 4/9, the deck (driving surface) is in poor shape, with advanced wear on file for this vintage.
- • The superstructure (beams and supports above the deck) is in critical condition (2/9), with severe deterioration recorded on the inspecting agency's 0-9 scale.
- • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.
Location
Data Source
FHWA National Bridge Inventory (NBI).
FHWA NBI Program ↗How to read this record
OFF PR 200 is in the federal Poor condition category. That is a component-based result, not a closure order.
- NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
- Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
- Compare OFF PR 200 against other structures in Vieques and across Puerto Rico. Puerto Rico bridges
- Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge
Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.
Frequently Asked Questions
What do the condition ratings mean for OFF PR 200?
OFF PR 200 in Vieques, Puerto Rico has a deck rating of 4/9, superstructure rating of 2/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.
How often is OFF PR 200 inspected?
OFF PR 200's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 500 vehicles per day.
What does “structurally deficient” mean in older bridge reports?
FHWA retired that reported status beginning with the 2018 archive. OFF PR 200 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.
What is the inventory load rating for OFF PR 200?
OFF PR 200 has an NBI inventory load rating of 2.7 metric tons.
Who is responsible for maintaining OFF PR 200?
OFF PR 200 is owned and maintained by City/Municipal Highway Agency.
How old is OFF PR 200 and does age affect safety?
OFF PR 200 was built in 1930, making it 96 years old.
Share this inspection record
Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.
Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.