FHWA NBI 2024 Inspection record Public-domain dataset

OFF PR 588 AT 0.30

Carrying OFF PR 588 AT 0.30 over CHIQUITO RIVER

AT NORTH OF PR 588, Ponce, Puerto Rico

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
26 t Inventory load rating Lower than 69% of rated Puerto Rico bridges

OFF PR 588 AT 0.30 in Ponce, Puerto Rico sits above 31% of rated Puerto Rico bridges on inventory load rating (26 t), while its 2009 build year is earlier than 11% of Ponce's recorded-year cohort (123 bridges).

OFF PR 588 AT 0.30 in Ponce, Puerto Rico is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 2009, it carries 1 rated component on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure PR:029141

POST-2000 · STEEL · LONG-SPAN-RUN · CULVERT-LED · LOCAL-ADT · STANDARD-LOAD · CAT-POOR

  • POST-2000 2000+
  • STEEL Steel
  • LONG-SPAN-RUN 4 spans
  • CULVERT-LED Culvert-led
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Structural health score

A composite of the deck, superstructure, and substructure NBI condition ratings plus the inventory load rating, benchmarked against the full national bridge corpus, distinct from the Good/Fair/Poor category above.

F
Overall Score
25/100
OFF PR 588 AT 0.30
Deck Condition N/A
N/A
NBI deck condition rating
Superstructure Condition N/A
N/A
NBI superstructure condition rating
Substructure Condition N/A
N/A
NBI substructure condition rating
Load Rating F
26 t
NBI inventory load rating vs the national corpus

Bridge Snapshot: OFF PR 588 AT 0.30

The OFF PR 588 AT 0.30 bridge in Ponce, Puerto Rico carries OFF PR 588 AT 0.30 over CHIQUITO RIVER. It was built in 2009, making it 17 years old today. The structure is built primarily of steel and spans 4 sections, stretching 8.9 meters (29 feet) end to end. Daily traffic averages 100 vehicles, placing it in the lower-traffic tier of Puerto Rico bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection places the weakest component in poor condition (see the full component ratings below). At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules.

How OFF PR 588 AT 0.30 compares

▼ 12.3
Load rating vs Puerto Rico average (37.8 t; 2,385 rated)
123
Bridges in Ponce · 19 in Poor condition

Age against the county: built in 2009, earlier than 14 of Ponce's 123 bridges with a recorded construction year (11%), against a county median build year of 1992. This is one of the newer structures in its county.

OFF PR 588 AT 0.30 25.5 t
Puerto Rico average (2,385 rated) 37.8 t

Live comparison across Puerto Rico bridges with a recorded inventory load rating (2,385 rated).

OFF PR 588 AT 0.30 vs every rated Puerto Rico bridge

Inventory load rating (metric tons), FHWA NBI, this state

26 Top 69% higher than 31% of 2,385 bridges

rated Puerto Rico bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Culvert
4/9
Poor (1–4)
Inventory Load Rating
25.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Ponce inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 123 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
2009
Material
Steel
Number of Spans
4
Structure Length
8.9 m (29 ft)
Deck Width
4.2 m (14 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
100 vehicles/day
Structure Number
029141

How to read this record

OFF PR 588 AT 0.30 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare OFF PR 588 AT 0.30 against other structures in Ponce and across Puerto Rico. Puerto Rico bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for OFF PR 588 AT 0.30?

OFF PR 588 AT 0.30 in Ponce, Puerto Rico on the FHWA's 0–9 scale.

How often is OFF PR 588 AT 0.30 inspected?

OFF PR 588 AT 0.30's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 100 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. OFF PR 588 AT 0.30 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for OFF PR 588 AT 0.30?

OFF PR 588 AT 0.30 has an NBI inventory load rating of 25.5 metric tons.

Who is responsible for maintaining OFF PR 588 AT 0.30?

OFF PR 588 AT 0.30 is owned and maintained by City/Municipal Highway Agency.

How old is OFF PR 588 AT 0.30 and does age affect safety?

OFF PR 588 AT 0.30 was built in 2009, making it 17 years old.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.