FHWA NBI 2024 Inspection record Public-domain dataset

SD037

Carrying SD037 over 4TH AVE BNSF RR

1.4 N I 90 INTERCHANGE, Davison, South Dakota

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
41 t Inventory load rating Higher than 78% of rated South Dakota bridges

SD037 in Davison, South Dakota sits above 78% of rated South Dakota bridges on inventory load rating (41 t), while its 1997 build year is earlier than 25% of Davison's recorded-year cohort (123 bridges).

SD037 in Davison, South Dakota is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1997, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure SD:000000018141093

LATE-CENTURY · PRESTRESS · MULTI-SPAN · TIED-CTRL · ARTERIAL-ADT · HEAVY-LOAD · CAT-GOOD

  • LATE-CENTURY 1980–1999
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 3 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • HEAVY-LOAD Heavy load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SD037

The SD037 bridge in Davison, South Dakota carries SD037 over 4TH AVE BNSF RR. It was built in 1997, making it 29 years old today. The structure is built primarily of prestressed concrete continuous and spans 3 sections, stretching 71.6 meters (235 feet) end to end. Daily traffic averages 7,162 vehicles, placing it in the moderately-trafficked tier of South Dakota bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range.

How SD037 compares

▲ 8.3
Load rating vs South Dakota average (32.5 t; 5,886 of 5,887 rated)
123
Bridges in Davison · 21 in Poor condition

Age against the county: built in 1997, earlier than 31 of Davison's 123 bridges with a recorded construction year (25%), against a county median build year of 1970. This is one of the newer structures in its county.

SD037 40.8 t
South Dakota average (5,886 of 5,887 rated) 32.5 t

Live comparison across South Dakota bridges with a recorded inventory load rating (5,886 of 5,887 rated).

SD037 vs every rated South Dakota bridge

Inventory load rating (metric tons), FHWA NBI, this state

41 Top 22% higher than 78% of 5,886 bridges

rated South Dakota bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
40.8 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Davison inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 123 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1997
Material
Prestressed Concrete Continuous
Number of Spans
3
Structure Length
71.6 m (235 ft)
Deck Width
19.4 m (64 ft)
Owner
State Highway Agency
Avg Daily Traffic
7,162 vehicles/day
Structure Number
000000018141093

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether SD037 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SD037 against other structures in Davison and across South Dakota. South Dakota bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SD037?

SD037 in Davison, South Dakota has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SD037 inspected?

SD037's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 7,162 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SD037 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SD037?

SD037 has an NBI inventory load rating of 40.8 metric tons.

Who is responsible for maintaining SD037?

SD037 is owned and maintained by State Highway Agency.

How old is SD037 and does age affect safety?

SD037 was built in 1997, making it 29 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.