FHWA NBI 2024 Inspection record Public-domain dataset

Main Ave in Vivian

Carrying Main Ave in Vivian over Medicine Creek

0.3S of Vivian, Lyman, South Dakota

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
30 t Inventory load rating Higher than 55% of rated South Dakota bridges

Main Ave in Vivian in Lyman, South Dakota sits above 55% of rated South Dakota bridges on inventory load rating (30 t), while its 2004 build year is earlier than 13% of Lyman's recorded-year cohort (114 bridges).

Main Ave in Vivian in Lyman, South Dakota is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 2004, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure SD:000000043037189

POST-2000 · CONCRETE · MULTI-SPAN · TIED-CTRL · LOCAL-ADT · STANDARD-LOAD · CAT-GOOD

  • POST-2000 2000+
  • CONCRETE Concrete
  • MULTI-SPAN 3 spans
  • TIED-CTRL Tied control
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: Main Ave in Vivian

The Main Ave in Vivian bridge in Lyman, South Dakota carries Main Ave in Vivian over Medicine Creek. It was built in 2004, making it 22 years old today. The structure is built primarily of concrete continuous and spans 3 sections, stretching 31.2 meters (102 feet) end to end. Daily traffic averages 130 vehicles, placing it in the lower-traffic tier of South Dakota bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range.

How Main Ave in Vivian compares

▼ 2.5
Load rating vs South Dakota average (32.5 t; 5,886 of 5,887 rated)
114
Bridges in Lyman · 11 in Poor condition

Age against the county: built in 2004, earlier than 15 of Lyman's 114 bridges with a recorded construction year (13%), against a county median build year of 1971. This is one of the newer structures in its county.

Main Ave in Vivian 30.0 t
South Dakota average (5,886 of 5,887 rated) 32.5 t

Live comparison across South Dakota bridges with a recorded inventory load rating (5,886 of 5,887 rated).

Main Ave in Vivian vs every rated South Dakota bridge

Inventory load rating (metric tons), FHWA NBI, this state

30 Top 45% higher than 55% of 5,886 bridges

rated South Dakota bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
30.0 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Lyman inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 114 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
2004
Material
Concrete Continuous
Number of Spans
3
Structure Length
31.2 m (102 ft)
Deck Width
9.1 m (30 ft)
Owner
County Highway Agency
Avg Daily Traffic
130 vehicles/day
Structure Number
000000043037189

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether Main Ave in Vivian is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare Main Ave in Vivian against other structures in Lyman and across South Dakota. South Dakota bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for Main Ave in Vivian?

Main Ave in Vivian in Lyman, South Dakota has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is Main Ave in Vivian inspected?

Main Ave in Vivian's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 130 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. Main Ave in Vivian is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for Main Ave in Vivian?

Main Ave in Vivian has an NBI inventory load rating of 30.0 metric tons.

Who is responsible for maintaining Main Ave in Vivian?

Main Ave in Vivian is owned and maintained by County Highway Agency.

How old is Main Ave in Vivian and does age affect safety?

Main Ave in Vivian was built in 2004, making it 22 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.