FHWA NBI 2024 Inspection record Public-domain dataset

SD011

Carrying SD011 over WEST PIPESTONE CK

2.9 N I 90 INTERCH, Minnehaha, South Dakota

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
35 t Inventory load rating Higher than 67% of rated South Dakota bridges

SD011 in Minnehaha, South Dakota sits above 67% of rated South Dakota bridges on inventory load rating (35 t), while its 1953 build year is earlier than 88% of Minnehaha's recorded-year cohort (393 bridges).

SD011 in Minnehaha, South Dakota is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1953, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure SD:000000050280136

INTERSTATE-ERA · CONCRETE · LONG-SPAN-RUN · SUB-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • LONG-SPAN-RUN 5 spans
  • SUB-LED Substructure-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SD011

The SD011 bridge in Minnehaha, South Dakota carries SD011 over WEST PIPESTONE CK. It was built in 1953, making it 73 years old today. The structure is built primarily of concrete continuous and spans 5 sections, stretching 56.7 meters (186 feet) end to end. Daily traffic averages 3,797 vehicles, placing it in the moderately-trafficked tier of South Dakota bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How SD011 compares

▲ 2.1
Load rating vs South Dakota average (32.5 t; 5,886 of 5,887 rated)
393
Bridges in Minnehaha · 37 in Poor condition

Age against the county: built in 1953, earlier than 347 of Minnehaha's 393 bridges with a recorded construction year (88%), against a county median build year of 1990. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

SD011 34.6 t
South Dakota average (5,886 of 5,887 rated) 32.5 t

Live comparison across South Dakota bridges with a recorded inventory load rating (5,886 of 5,887 rated).

SD011 vs every rated South Dakota bridge

Inventory load rating (metric tons), FHWA NBI, this state

35 Top 33% higher than 67% of 5,886 bridges

rated South Dakota bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
34.6 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Minnehaha inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 393 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1953
Material
Concrete Continuous
Number of Spans
5
Structure Length
56.7 m (186 ft)
Deck Width
10.5 m (34 ft)
Owner
State Highway Agency
Avg Daily Traffic
3,797 vehicles/day
Structure Number
000000050280136

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.

How to read this record

SD011 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SD011 against other structures in Minnehaha and across South Dakota. South Dakota bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SD011?

SD011 in Minnehaha, South Dakota has a deck rating of 7/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is SD011 inspected?

SD011's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 3,797 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SD011 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SD011?

SD011 has an NBI inventory load rating of 34.6 metric tons.

Who is responsible for maintaining SD011?

SD011 is owned and maintained by State Highway Agency.

How old is SD011 and does age affect safety?

SD011 was built in 1953, making it 73 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.