FHWA NBI 2024 Inspection record Public-domain dataset

Spencer Parkway

Carrying Spencer Parkway over Draw

300 Ft N Battlement Pkwy, Garfield, Colorado

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
33 t Inventory load rating

Bridge Snapshot: Spencer Parkway

The Spencer Parkway bridge in Garfield, Colorado carries Spencer Parkway over Draw. It was built in 1981, making it 45 years old today. The structure is built primarily of prestressed concrete and spans 2 sections, stretching 43.9 meters (144 feet) end to end. Daily traffic averages 1,590 vehicles, placing it in the moderately-trafficked tier of Colorado bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 32.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How Spencer Parkway compares

▼ 4.4
Load rating vs Colorado average (37.1 t)
Bottom 42%
Lower load rating than 58% of Colorado bridges
167
Bridges in Garfield · 2 in Poor condition
Spencer Parkway 32.7 t
Colorado average 37.1 t

Live comparison across Colorado.

Historical Sufficiency Rating

PlainBridge-computed
97.6 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
30.0
Essentiality /15
14.6
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
32.7 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1981
Material
Prestressed Concrete
Number of Spans
2
Structure Length
43.9 m (144 ft)
Deck Width
18.3 m (60 ft)
Owner
County Highway Agency
Avg Daily Traffic
1,590 vehicles/day
Structure Number
SPENCER PKWY

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether Spencer Parkway is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare Spencer Parkway against other structures in Garfield and across Colorado. Colorado bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for Spencer Parkway?

Spencer Parkway in Garfield, Colorado has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is Spencer Parkway inspected?

Spencer Parkway's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,590 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. Spencer Parkway is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for Spencer Parkway?

Spencer Parkway has an NBI inventory load rating of 32.7 metric tons.

Who is responsible for maintaining Spencer Parkway?

Spencer Parkway is owned and maintained by County Highway Agency.

How old is Spencer Parkway and does age affect safety?

Spencer Parkway was built in 1981, making it 45 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.