FHWA NBI 2024 Inspection record Public-domain dataset

S UNIVERSITY DR SB

Carrying S UNIVERSITY DR SB over CLEAR FORK TRINITY RIVER

0.7 MI S OF IH 30, Tarrant, Texas

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
13 t Inventory load rating Lower than 99% of rated Texas bridges

S UNIVERSITY DR SB in Tarrant, Texas sits above 1% of rated Texas bridges on inventory load rating (13 t), while its 1936 build year is earlier than 99% of Tarrant's recorded-year cohort (2,617 bridges).

S UNIVERSITY DR SB in Tarrant, Texas is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1936, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure TX:022200ZU4000006

PRE-1950 · STEEL · SINGLE-SPAN · TIED-CTRL · HEAVY-ADT · LIGHT-LOAD · CAT-FAIR

  • PRE-1950 Pre-1950
  • STEEL Steel
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • HEAVY-ADT Heavy ADT
  • LIGHT-LOAD Light load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: S UNIVERSITY DR SB

The S UNIVERSITY DR SB bridge in Tarrant, Texas carries S UNIVERSITY DR SB over CLEAR FORK TRINITY RIVER. It was built in 1936, making it 90 years old today. It was last reconstructed in 1967, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 102.4 meters (336 feet) end to end. Daily traffic averages 16,255 vehicles, placing it in the heavily-trafficked tier of Texas bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range.

How S UNIVERSITY DR SB compares

▼ 16.3
Load rating vs Texas average (29.0 t; 56,715 of 56,729 rated)
2,617
Bridges in Tarrant · 10 in Poor condition

Age against the county: built in 1936, earlier than 2,580 of Tarrant's 2,617 bridges with a recorded construction year (99%), against a county median build year of 1991. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

S UNIVERSITY DR SB 12.7 t
Texas average (56,715 of 56,729 rated) 29.0 t

Live comparison across Texas bridges with a recorded inventory load rating (56,715 of 56,729 rated).

S UNIVERSITY DR SB vs every rated Texas bridge

Inventory load rating (metric tons), FHWA NBI, this state

13 Top 99% higher than 1% of 56,715 bridges

rated Texas bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
12.7 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Tarrant inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 2,617 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1936
Last Reconstructed
1967
Material
Steel
Number of Spans
1
Structure Length
102.4 m (336 ft)
Deck Width
11.4 m (37 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
16,255 vehicles/day
Structure Number
022200ZU4000006

Condition Analysis

  • The deck (driving surface) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether S UNIVERSITY DR SB is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare S UNIVERSITY DR SB against other structures in Tarrant and across Texas. Texas bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for S UNIVERSITY DR SB?

S UNIVERSITY DR SB in Tarrant, Texas has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is S UNIVERSITY DR SB inspected?

S UNIVERSITY DR SB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 16,255 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. S UNIVERSITY DR SB is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for S UNIVERSITY DR SB?

S UNIVERSITY DR SB has an NBI inventory load rating of 12.7 metric tons.

Who is responsible for maintaining S UNIVERSITY DR SB?

S UNIVERSITY DR SB is owned and maintained by City/Municipal Highway Agency.

How old is S UNIVERSITY DR SB and does age affect safety?

S UNIVERSITY DR SB was built in 1936, making it 90 years old and last reconstructed in 1967.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.