FHWA NBI 2024 Inspection record Public-domain dataset

SPUR 290 SB

Carrying SPUR 290 SB over BNSF RR & AVE B

0.20 MI S OF SH 53, Bell, Texas

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
31 t Inventory load rating Higher than 50% of rated Texas bridges

SPUR 290 SB in Bell, Texas sits above 50% of rated Texas bridges on inventory load rating (31 t), while its 1966 build year is earlier than 74% of Bell's recorded-year cohort (660 bridges).

SPUR 290 SB in Bell, Texas is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1966, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure TX:090140032001092

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · TIED-CTRL · ARTERIAL-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 4 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SPUR 290 SB

The SPUR 290 SB bridge in Bell, Texas carries SPUR 290 SB over BNSF RR & AVE B. It was built in 1966, making it 60 years old today. The structure is built primarily of steel continuous and spans 4 sections, stretching 179.8 meters (590 feet) end to end. Daily traffic averages 5,351 vehicles, placing it in the moderately-trafficked tier of Texas bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How SPUR 290 SB compares

▲ 1.8
Load rating vs Texas average (29.0 t; 56,715 of 56,729 rated)
660
Bridges in Bell · 2 in Poor condition

Age against the county: built in 1966, earlier than 489 of Bell's 660 bridges with a recorded construction year (74%), against a county median build year of 1984. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

SPUR 290 SB 30.8 t
Texas average (56,715 of 56,729 rated) 29.0 t

Live comparison across Texas bridges with a recorded inventory load rating (56,715 of 56,729 rated).

SPUR 290 SB vs every rated Texas bridge

Inventory load rating (metric tons), FHWA NBI, this state

31 Top 50% higher than 50% of 56,715 bridges

rated Texas bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
30.8 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Bell inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 660 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1966
Material
Steel Continuous
Number of Spans
4
Structure Length
179.8 m (590 ft)
Deck Width
12.6 m (41 ft)
Owner
State Highway Agency
Avg Daily Traffic
5,351 vehicles/day
Structure Number
090140032001092

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether SPUR 290 SB is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SPUR 290 SB against other structures in Bell and across Texas. Texas bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SPUR 290 SB?

SPUR 290 SB in Bell, Texas has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SPUR 290 SB inspected?

SPUR 290 SB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5,351 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SPUR 290 SB is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SPUR 290 SB?

SPUR 290 SB has an NBI inventory load rating of 30.8 metric tons.

Who is responsible for maintaining SPUR 290 SB?

SPUR 290 SB is owned and maintained by State Highway Agency.

How old is SPUR 290 SB and does age affect safety?

SPUR 290 SB was built in 1966, making it 60 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.