FHWA NBI 2024 Inspection record Public-domain dataset

IH 35E NBFR

Carrying IH 35E NBFR over UP RAILROAD

0.20 MI E OF US 377, Denton, Texas

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
54 t Inventory load rating Higher than 99% of rated Texas bridges

IH 35E NBFR in Denton, Texas sits above 99% of rated Texas bridges on inventory load rating (54 t), while its 1958 build year is earlier than 89% of Denton's recorded-year cohort (991 bridges).

IH 35E NBFR in Denton, Texas is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1958, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure TX:180610019503087

INTERSTATE-ERA · PRESTRESS · SINGLE-SPAN · DECK-LED · ARTERIAL-ADT · HEAVY-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • SINGLE-SPAN Single span
  • DECK-LED Deck-led
  • ARTERIAL-ADT Arterial ADT
  • HEAVY-LOAD Heavy load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: IH 35E NBFR

The IH 35E NBFR bridge in Denton, Texas carries IH 35E NBFR over UP RAILROAD. It was built in 1958, making it 68 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 52.1 meters (171 feet) end to end. Daily traffic averages 7,290 vehicles, placing it in the moderately-trafficked tier of Texas bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How IH 35E NBFR compares

▲ 25.4
Load rating vs Texas average (29.0 t; 56,715 of 56,729 rated)
991
Bridges in Denton · 9 in Poor condition

Age against the county: built in 1958, earlier than 882 of Denton's 991 bridges with a recorded construction year (89%), against a county median build year of 1999. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

IH 35E NBFR 54.4 t
Texas average (56,715 of 56,729 rated) 29.0 t

Live comparison across Texas bridges with a recorded inventory load rating (56,715 of 56,729 rated).

IH 35E NBFR vs every rated Texas bridge

Inventory load rating (metric tons), FHWA NBI, this state

54 Top 1% higher than 99% of 56,715 bridges

rated Texas bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
54.4 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Denton inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 991 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1958
Material
Prestressed Concrete
Number of Spans
1
Structure Length
52.1 m (171 ft)
Deck Width
9.5 m (31 ft)
Owner
State Highway Agency
Avg Daily Traffic
7,290 vehicles/day
Structure Number
180610019503087

Condition Analysis

  • The deck (driving surface) is in poor condition (4/9), showing advanced deterioration on the inspecting agency's 0-9 scale.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

IH 35E NBFR is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare IH 35E NBFR against other structures in Denton and across Texas. Texas bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for IH 35E NBFR?

IH 35E NBFR in Denton, Texas has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is IH 35E NBFR inspected?

IH 35E NBFR's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 7,290 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. IH 35E NBFR is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for IH 35E NBFR?

IH 35E NBFR has an NBI inventory load rating of 54.4 metric tons.

Who is responsible for maintaining IH 35E NBFR?

IH 35E NBFR is owned and maintained by State Highway Agency.

How old is IH 35E NBFR and does age affect safety?

IH 35E NBFR was built in 1958, making it 68 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.