FHWA NBI 2024 Inspection record Public-domain dataset

S BRDG RD/FAU5164

Carrying S BRDG RD/FAU5164 over BIG PAPILLION CREEK

S BRIDGE ROAD @ 111TH ST, Douglas, Nebraska

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
32 t Inventory load rating

Bridge Snapshot: S BRDG RD/FAU5164

The S BRDG RD/FAU5164 bridge in Douglas, Nebraska carries S BRDG RD/FAU5164 over BIG PAPILLION CREEK. It was built in 1970, making it 56 years old today. It was last reconstructed in 2004, extending its service life. The structure is built primarily of prestressed concrete continuous and spans 3 sections, stretching 80.2 meters (263 feet) end to end. Daily traffic averages 14,690 vehicles, placing it in the heavily-trafficked tier of Nebraska bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 32.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How S BRDG RD/FAU5164 compares

▲ 4.3
Load rating vs Nebraska average (27.7 t)
Top 41%
Higher load rating than 59% of Nebraska bridges
563
Bridges in Douglas · 10 in Poor condition
S BRDG RD/FAU5164 32.0 t
Nebraska average 27.7 t

Live comparison across Nebraska.

Historical Sufficiency Rating

PlainBridge-computed
86.1 / 100 - historical 80–100 band
Structural adequacy /55
54.9
Serviceability /30
30.0
Essentiality /15
1.2
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
32.0 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1970
Last Reconstructed
2004
Material
Prestressed Concrete Continuous
Number of Spans
3
Structure Length
80.2 m (263 ft)
Deck Width
20.9 m (69 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
14,690 vehicles/day
Structure Number
U1825C2005

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether S BRDG RD/FAU5164 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare S BRDG RD/FAU5164 against other structures in Douglas and across Nebraska. Nebraska bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for S BRDG RD/FAU5164?

S BRDG RD/FAU5164 in Douglas, Nebraska has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is S BRDG RD/FAU5164 inspected?

S BRDG RD/FAU5164's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 14,690 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. S BRDG RD/FAU5164 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for S BRDG RD/FAU5164?

S BRDG RD/FAU5164 has an NBI inventory load rating of 32.0 metric tons.

Who is responsible for maintaining S BRDG RD/FAU5164?

S BRDG RD/FAU5164 is owned and maintained by City/Municipal Highway Agency.

How old is S BRDG RD/FAU5164 and does age affect safety?

S BRDG RD/FAU5164 was built in 1970, making it 56 years old and last reconstructed in 2004.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.