FHWA NBI 2024 Inspection record Public-domain dataset

10600 S.ST.FA#2078

Carrying 10600 S.ST.FA#2078 over JORDAN AND SALT LAKE C

100 E. 10600 S. SANDY, Salt Lake, Utah

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
19 t Inventory load rating Lower than 90% of rated Utah bridges

10600 S.ST.FA#2078 in Salt Lake, Utah sits above 10% of rated Utah bridges on inventory load rating (19 t), while its 1979 build year is earlier than 78% of Salt Lake's recorded-year cohort (659 bridges).

10600 S.ST.FA#2078 in Salt Lake, Utah is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1979, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure UT:035211F

INTERSTATE-ERA · PRESTRESS · SINGLE-SPAN · SUPER-LED · HEAVY-ADT · LIGHT-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • SINGLE-SPAN Single span
  • SUPER-LED Superstructure-led
  • HEAVY-ADT Heavy ADT
  • LIGHT-LOAD Light load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: 10600 S.ST.FA#2078

The 10600 S.ST.FA#2078 bridge in Salt Lake, Utah carries 10600 S.ST.FA#2078 over JORDAN AND SALT LAKE C. It was built in 1979, making it 47 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 6.7 meters (22 feet) end to end. Daily traffic averages 27,800 vehicles, placing it in the heavily-trafficked tier of Utah bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 4/9, substructure at 7/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules.

How 10600 S.ST.FA#2078 compares

▼ 17.0
Load rating vs Utah average (36.4 t; 3,113 of 3,125 rated)
659
Bridges in Salt Lake · 25 in Poor condition

Age against the county: built in 1979, earlier than 514 of Salt Lake's 659 bridges with a recorded construction year (78%), against a county median build year of 1998. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

10600 S.ST.FA#2078 19.4 t
Utah average (3,113 of 3,125 rated) 36.4 t

Live comparison across Utah bridges with a recorded inventory load rating (3,113 of 3,125 rated).

10600 S.ST.FA#2078 vs every rated Utah bridge

Inventory load rating (metric tons), FHWA NBI, this state

19 Top 90% higher than 10% of 3,113 bridges

rated Utah bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
7/9
Good (7–9)
Inventory Load Rating
19.4 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Salt Lake inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 659 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1979
Material
Prestressed Concrete
Number of Spans
1
Structure Length
6.7 m (22 ft)
Deck Width
24.4 m (80 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
27,800 vehicles/day
Structure Number
035211F

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear on file for this vintage.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

10600 S.ST.FA#2078 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare 10600 S.ST.FA#2078 against other structures in Salt Lake and across Utah. Utah bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 10600 S.ST.FA#2078?

10600 S.ST.FA#2078 in Salt Lake, Utah has a deck rating of 6/9, superstructure rating of 4/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is 10600 S.ST.FA#2078 inspected?

10600 S.ST.FA#2078's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 27,800 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 10600 S.ST.FA#2078 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 10600 S.ST.FA#2078?

10600 S.ST.FA#2078 has an NBI inventory load rating of 19.4 metric tons.

Who is responsible for maintaining 10600 S.ST.FA#2078?

10600 S.ST.FA#2078 is owned and maintained by City/Municipal Highway Agency.

How old is 10600 S.ST.FA#2078 and does age affect safety?

10600 S.ST.FA#2078 was built in 1979, making it 47 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.