FHWA NBI 2024 Inspection record Public-domain dataset

EXP ROUTE 0395

Carrying EXP ROUTE 0395 over FERN STREET EXT

00.37 27 / 00.24 110, Arlington, Virginia

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
45 t Inventory load rating Higher than 50% of rated Virginia bridges

EXP ROUTE 0395 in Arlington, Virginia sits above 50% of rated Virginia bridges on inventory load rating (45 t), while its 1976 build year is earlier than 33% of Arlington's recorded-year cohort (183 bridges).

EXP ROUTE 0395 in Arlington, Virginia is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1976, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure VA:000000000000309

INTERSTATE-ERA · STEEL · MULTI-SPAN · SUPER-LED · HEAVY-ADT · HEAVY-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • MULTI-SPAN 2 spans
  • SUPER-LED Superstructure-led
  • HEAVY-ADT Heavy ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Structural health score

A composite of the deck, superstructure, and substructure NBI condition ratings plus the inventory load rating, benchmarked against the full national bridge corpus, distinct from the Good/Fair/Poor category above.

D
Overall Score
41/100
EXP ROUTE 0395
Deck Condition C-
7/9
NBI deck condition rating (0=failed, 9=excellent)
Superstructure Condition F
5/9
NBI superstructure condition rating (0=failed, 9=excellent)
Substructure Condition F
6/9
NBI substructure condition rating (0=failed, 9=excellent)
Load Rating B+
45 t
NBI inventory load rating vs the national corpus

Bridge Snapshot: EXP ROUTE 0395

The EXP ROUTE 0395 bridge in Arlington, Virginia carries EXP ROUTE 0395 over FERN STREET EXT. It was built in 1976, making it 50 years old today. The structure is built primarily of steel and spans 2 sections, stretching 46.6 meters (153 feet) end to end. Daily traffic averages 21,393 vehicles, placing it in the heavily-trafficked tier of Virginia bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection places the weakest component in fair condition (see the full component ratings below). No reported major component scores in the Poor range under the current federal condition thresholds.

How EXP ROUTE 0395 compares

▼ 2.1
Load rating vs Virginia average (46.6 t; 14,112 of 14,120 rated)
183
Bridges in Arlington · 7 in Poor condition

Age against the county: built in 1976, earlier than 61 of Arlington's 183 bridges with a recorded construction year (33%), against a county median build year of 1973. This is one of the newer structures in its county.

EXP ROUTE 0395 44.5 t
Virginia average (14,112 of 14,120 rated) 46.6 t

Live comparison across Virginia bridges with a recorded inventory load rating (14,112 of 14,120 rated).

EXP ROUTE 0395 vs every rated Virginia bridge

Inventory load rating (metric tons), FHWA NBI, this state

45 Top 50% higher than 50% of 14,112 bridges

rated Virginia bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
5/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
44.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Arlington inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 183 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1976
Material
Steel
Number of Spans
2
Structure Length
46.6 m (153 ft)
Deck Width
40.2 m (132 ft)
Owner
State Highway Agency
Avg Daily Traffic
21,393 vehicles/day
Structure Number
000000000000309

Condition Analysis

  • • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether EXP ROUTE 0395 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare EXP ROUTE 0395 against other structures in Arlington and across Virginia. Virginia bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for EXP ROUTE 0395?

EXP ROUTE 0395 in Arlington, Virginia has a deck rating of 7/9, superstructure rating of 5/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is EXP ROUTE 0395 inspected?

EXP ROUTE 0395's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 21,393 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. EXP ROUTE 0395 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for EXP ROUTE 0395?

EXP ROUTE 0395 has an NBI inventory load rating of 44.5 metric tons.

Who is responsible for maintaining EXP ROUTE 0395?

EXP ROUTE 0395 is owned and maintained by State Highway Agency.

How old is EXP ROUTE 0395 and does age affect safety?

EXP ROUTE 0395 was built in 1976, making it 50 years old.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.