FHWA NBI 2024 Inspection record Public-domain dataset

C2002

Carrying C2002 over S. FORK EAST CREEK

0.3 MI TO JCT W VT73, Addison, Vermont

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
45 t Inventory load rating Higher than 68% of rated Vermont bridges

C2002 in Addison, Vermont is rated Fair in the FHWA's 2024 National Bridge Inventory.

Built in 1950, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure VT:100114000301141

INTERSTATE-ERA · STEEL · SINGLE-SPAN · SUB-LED · LOCAL-ADT · HEAVY-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • SINGLE-SPAN Single span
  • SUB-LED Substructure-led
  • LOCAL-ADT Local ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Structural health score

A composite of the deck, superstructure, and substructure NBI condition ratings plus the inventory load rating, benchmarked against the full national bridge corpus, distinct from the Good/Fair/Poor category above.

C-
Overall Score
51/100
C2002
Deck Condition C-
7/9
NBI deck condition rating (0=failed, 9=excellent)
Superstructure Condition C-
7/9
NBI superstructure condition rating (0=failed, 9=excellent)
Substructure Condition F
6/9
NBI substructure condition rating (0=failed, 9=excellent)
Load Rating B+
45 t
NBI inventory load rating vs the national corpus

Bridge Snapshot: C2002

The C2002 bridge in Addison, Vermont carries C2002 over S. FORK EAST CREEK. It was built in 1950, making it 76 years old today. It was last reconstructed in 1994, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 18.0 meters (59 feet) end to end. Daily traffic averages 460 vehicles, placing it in the lower-traffic tier of Vermont bridges. It is owned and maintained by Town/Township Highway Agency.

The latest FHWA inspection places the weakest component in fair condition (see the full component ratings below). All reported major components score above the Poor range.

How C2002 compares

▲ 7.1
Load rating vs Vermont average (37.4 t; 2,861 of 2,862 rated)
143
Bridges in Addison · 4 in Poor condition

Age against the county: built in 1950, earlier than 89 of Addison's 143 bridges with a recorded construction year (62%), against a county median build year of 1964. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

C2002 44.5 t
Vermont average (2,861 of 2,862 rated) 37.4 t

Live comparison across Vermont bridges with a recorded inventory load rating (2,861 of 2,862 rated).

C2002 vs every rated Vermont bridge

Inventory load rating (metric tons), FHWA NBI, this state

45 Top 32% higher than 68% of 2,861 bridges

rated Vermont bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
44.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Addison inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 143 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1950
Last Reconstructed
1994
Material
Steel
Number of Spans
1
Structure Length
18.0 m (59 ft)
Deck Width
7.8 m (26 ft)
Owner
Town/Township Highway Agency
Avg Daily Traffic
460 vehicles/day
Structure Number
100114000301141

Condition Analysis

  • • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether C2002 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare C2002 against other structures in Addison and across Vermont. Vermont bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for C2002?

C2002 in Addison, Vermont has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is C2002 inspected?

C2002's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 460 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. C2002 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for C2002?

C2002 has an NBI inventory load rating of 44.5 metric tons.

Who is responsible for maintaining C2002?

C2002 is owned and maintained by Town/Township Highway Agency.

How old is C2002 and does age affect safety?

C2002 was built in 1950, making it 76 years old and last reconstructed in 1994.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.