FHWA NBI 2024 Inspection record Public-domain dataset

C3022

Carrying C3022 over BROOK

AT JCT TH 2 + TH 22, Orange, Vermont

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
90 t Inventory load rating Higher than 99% of rated Vermont bridges

C3022 in Orange, Vermont sits above 99% of rated Vermont bridges on inventory load rating (90 t), while its 1919 build year is earlier than 89% of Orange's recorded-year cohort (208 bridges).

C3022 in Orange, Vermont is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1919, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure VT:100904003509041

PRE-1950 · CONCRETE · SINGLE-SPAN · SUB-LED · LOCAL-ADT · HEAVY-LOAD · CAT-GOOD

  • PRE-1950 Pre-1950
  • CONCRETE Concrete
  • SINGLE-SPAN Single span
  • SUB-LED Substructure-led
  • LOCAL-ADT Local ADT
  • HEAVY-LOAD Heavy load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: C3022

The C3022 bridge in Orange, Vermont carries C3022 over BROOK. It was built in 1919, making it 107 years old today. It was last reconstructed in 1997, extending its service life. The structure is built primarily of concrete and spans 1 section, stretching 7.0 meters (23 feet) end to end. Daily traffic averages 120 vehicles, placing it in the lower-traffic tier of Vermont bridges. It is owned and maintained by Town/Township Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 8/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range.

How C3022 compares

▲ 52.4
Load rating vs Vermont average (37.4 t; 2,861 of 2,862 rated)
208
Bridges in Orange · 4 in Poor condition

Age against the county: built in 1919, earlier than 185 of Orange's 208 bridges with a recorded construction year (89%), against a county median build year of 1967. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

C3022 89.8 t
Vermont average (2,861 of 2,862 rated) 37.4 t

Live comparison across Vermont bridges with a recorded inventory load rating (2,861 of 2,862 rated).

C3022 vs every rated Vermont bridge

Inventory load rating (metric tons), FHWA NBI, this state

90 Top 1% higher than 99% of 2,861 bridges

rated Vermont bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
89.8 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Orange inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 208 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1919
Last Reconstructed
1997
Material
Concrete
Number of Spans
1
Structure Length
7.0 m (23 ft)
Deck Width
6.5 m (21 ft)
Owner
Town/Township Highway Agency
Avg Daily Traffic
120 vehicles/day
Structure Number
100904003509041

Condition Analysis

  • At 8/9, the deck (driving surface) is in good shape and shows no significant wear.
  • At 8/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether C3022 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare C3022 against other structures in Orange and across Vermont. Vermont bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for C3022?

C3022 in Orange, Vermont has a deck rating of 8/9, superstructure rating of 8/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is C3022 inspected?

C3022's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 120 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. C3022 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for C3022?

C3022 has an NBI inventory load rating of 89.8 metric tons.

Who is responsible for maintaining C3022?

C3022 is owned and maintained by Town/Township Highway Agency.

How old is C3022 and does age affect safety?

C3022 was built in 1919, making it 107 years old and last reconstructed in 1997.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.