FHWA NBI 2024 Inspection record Public-domain dataset

VT 00100 ML

Carrying VT 00100 ML over EAST BRANCH MISSISQUOI

1.5 MI S JCT. VT.58, Orleans, Vermont

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
21 t Inventory load rating Lower than 84% of rated Vermont bridges

VT 00100 ML in Orleans, Vermont sits above 16% of rated Vermont bridges on inventory load rating (21 t), while its 1929 build year is earlier than 86% of Orleans's recorded-year cohort (181 bridges).

VT 00100 ML in Orleans, Vermont is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1929, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure VT:200029023410132

PRE-1950 · CONCRETE · SINGLE-SPAN · SUPER-LED · ARTERIAL-ADT · STANDARD-LOAD · CAT-POOR

  • PRE-1950 Pre-1950
  • CONCRETE Concrete
  • SINGLE-SPAN Single span
  • SUPER-LED Superstructure-led
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: VT 00100 ML

The VT 00100 ML bridge in Orleans, Vermont carries VT 00100 ML over EAST BRANCH MISSISQUOI. It was built in 1929, making it 97 years old today. It was last reconstructed in 1948, extending its service life. The structure is built primarily of concrete and spans 1 section, stretching 13.1 meters (43 feet) end to end. Daily traffic averages 2,600 vehicles, placing it in the moderately-trafficked tier of Vermont bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 6/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed.

How VT 00100 ML compares

▼ 16.5
Load rating vs Vermont average (37.4 t; 2,861 of 2,862 rated)
181
Bridges in Orleans · 5 in Poor condition

Age against the county: built in 1929, earlier than 156 of Orleans's 181 bridges with a recorded construction year (86%), against a county median build year of 1971. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

VT 00100 ML 20.9 t
Vermont average (2,861 of 2,862 rated) 37.4 t

Live comparison across Vermont bridges with a recorded inventory load rating (2,861 of 2,862 rated).

VT 00100 ML vs every rated Vermont bridge

Inventory load rating (metric tons), FHWA NBI, this state

21 Top 84% higher than 16% of 2,861 bridges

rated Vermont bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
20.9 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Orleans inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 181 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1929
Last Reconstructed
1948
Material
Concrete
Number of Spans
1
Structure Length
13.1 m (43 ft)
Deck Width
10.1 m (33 ft)
Owner
State Highway Agency
Avg Daily Traffic
2,600 vehicles/day
Structure Number
200029023410132

Condition Analysis

  • The deck (driving surface) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear on file for this vintage.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

VT 00100 ML is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare VT 00100 ML against other structures in Orleans and across Vermont. Vermont bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for VT 00100 ML?

VT 00100 ML in Orleans, Vermont has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is VT 00100 ML inspected?

VT 00100 ML's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,600 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. VT 00100 ML is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for VT 00100 ML?

VT 00100 ML has an NBI inventory load rating of 20.9 metric tons.

Who is responsible for maintaining VT 00100 ML?

VT 00100 ML is owned and maintained by State Highway Agency.

How old is VT 00100 ML and does age affect safety?

VT 00100 ML was built in 1929, making it 97 years old and last reconstructed in 1948.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.