FHWA NBI 2024 Inspection record Public-domain dataset

TR 03 FAS 155

Carrying TR 03 FAS 155 over VERMONT RAILWAY

0.2 MI W JCT. VT.3, Rutland, Vermont

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
16 t Inventory load rating Lower than 90% of rated Vermont bridges

TR 03 FAS 155 in Rutland, Vermont sits above 10% of rated Vermont bridges on inventory load rating (16 t), while its 1920 build year is earlier than 92% of Rutland's recorded-year cohort (266 bridges).

TR 03 FAS 155 in Rutland, Vermont is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1920, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 5. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure VT:200155000111182

PRE-1950 · STEEL · SINGLE-SPAN · TIED-CTRL · LOCAL-ADT · LIGHT-LOAD · CAT-FAIR

  • PRE-1950 Pre-1950
  • STEEL Steel
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • LOCAL-ADT Local ADT
  • LIGHT-LOAD Light load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: TR 03 FAS 155

The TR 03 FAS 155 bridge in Rutland, Vermont carries TR 03 FAS 155 over VERMONT RAILWAY. It was built in 1920, making it 106 years old today. It was last reconstructed in 1939, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 11.0 meters (36 feet) end to end. Daily traffic averages 250 vehicles, placing it in the lower-traffic tier of Vermont bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How TR 03 FAS 155 compares

▼ 21.1
Load rating vs Vermont average (37.4 t; 2,861 of 2,862 rated)
266
Bridges in Rutland · 7 in Poor condition

Age against the county: built in 1920, earlier than 244 of Rutland's 266 bridges with a recorded construction year (92%), against a county median build year of 1971. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

TR 03 FAS 155 16.3 t
Vermont average (2,861 of 2,862 rated) 37.4 t

Live comparison across Vermont bridges with a recorded inventory load rating (2,861 of 2,862 rated).

TR 03 FAS 155 vs every rated Vermont bridge

Inventory load rating (metric tons), FHWA NBI, this state

16 Top 90% higher than 10% of 2,861 bridges

rated Vermont bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
16.3 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Rutland inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 266 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1920
Last Reconstructed
1939
Material
Steel
Number of Spans
1
Structure Length
11.0 m (36 ft)
Deck Width
11.4 m (37 ft)
Owner
State Highway Agency
Avg Daily Traffic
250 vehicles/day
Structure Number
200155000111182

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether TR 03 FAS 155 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare TR 03 FAS 155 against other structures in Rutland and across Vermont. Vermont bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for TR 03 FAS 155?

TR 03 FAS 155 in Rutland, Vermont has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is TR 03 FAS 155 inspected?

TR 03 FAS 155's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 250 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. TR 03 FAS 155 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for TR 03 FAS 155?

TR 03 FAS 155 has an NBI inventory load rating of 16.3 metric tons.

Who is responsible for maintaining TR 03 FAS 155?

TR 03 FAS 155 is owned and maintained by State Highway Agency.

How old is TR 03 FAS 155 and does age affect safety?

TR 03 FAS 155 was built in 1920, making it 106 years old and last reconstructed in 1939.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.