FHWA NBI 2024 Inspection record Public-domain dataset

SR 520

Carrying SR 520 over SR 202 & BIKE PATH

5.8 E JCT I-405, King, Washington

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
43 t Inventory load rating Higher than 78% of rated Washington bridges

SR 520 in King, Washington sits above 78% of rated Washington bridges on inventory load rating (43 t), while its 1995 build year is earlier than 27% of King's recorded-year cohort (1,238 bridges).

SR 520 in King, Washington is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1995, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure WA:0014444B0000000

LATE-CENTURY · PRESTRESS · LONG-SPAN-RUN · TIED-CTRL · HEAVY-ADT · HEAVY-LOAD · CAT-FAIR

  • LATE-CENTURY 1980–1999
  • PRESTRESS Prestressed concrete
  • LONG-SPAN-RUN 5 spans
  • TIED-CTRL Tied control
  • HEAVY-ADT Heavy ADT
  • HEAVY-LOAD Heavy load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: SR 520

The SR 520 bridge in King, Washington carries SR 520 over SR 202 & BIKE PATH. It was built in 1995, making it 31 years old today. It was last reconstructed in 2010, extending its service life. The structure is built primarily of prestressed concrete continuous and spans 5 sections, stretching 141.1 meters (463 feet) end to end. Daily traffic averages 33,541 vehicles, placing it in the heavily-trafficked tier of Washington bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How SR 520 compares

▲ 8.6
Load rating vs Washington average (34.0 t; 8,455 of 8,474 rated)
1,238
Bridges in King · 53 in Poor condition

Age against the county: built in 1995, earlier than 333 of King's 1,238 bridges with a recorded construction year (27%), against a county median build year of 1972. This is one of the newer structures in its county.

SR 520 42.6 t
Washington average (8,455 of 8,474 rated) 34.0 t

Live comparison across Washington bridges with a recorded inventory load rating (8,455 of 8,474 rated).

SR 520 vs every rated Washington bridge

Inventory load rating (metric tons), FHWA NBI, this state

43 Top 22% higher than 78% of 8,455 bridges

rated Washington bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
42.6 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

King inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 1,238 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1995
Last Reconstructed
2010
Material
Prestressed Concrete Continuous
Number of Spans
5
Structure Length
141.1 m (463 ft)
Deck Width
31.9 m (105 ft)
Owner
State Highway Agency
Avg Daily Traffic
33,541 vehicles/day
Structure Number
0014444B0000000

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether SR 520 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SR 520 against other structures in King and across Washington. Washington bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 520?

SR 520 in King, Washington has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SR 520 inspected?

SR 520's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 33,541 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 520 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 520?

SR 520 has an NBI inventory load rating of 42.6 metric tons.

Who is responsible for maintaining SR 520?

SR 520 is owned and maintained by State Highway Agency.

How old is SR 520 and does age affect safety?

SR 520 was built in 1995, making it 31 years old and last reconstructed in 2010.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.