FHWA NBI 2024 Inspection record Public-domain dataset

DEER PARK-MILAN RD

Carrying DEER PARK-MILAN RD over LITTLE SPOKANE RIVER

00.2 W MILAN, Spokane, Washington

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
16 t Inventory load rating Lower than 92% of rated Washington bridges

DEER PARK-MILAN RD in Spokane, Washington sits above 8% of rated Washington bridges on inventory load rating (16 t), while its 1954 build year is earlier than 85% of Spokane's recorded-year cohort (307 bridges).

DEER PARK-MILAN RD in Spokane, Washington is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1954, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure WA:084740000000000

INTERSTATE-ERA · CONCRETE · MULTI-SPAN · SUPER-LED · ARTERIAL-ADT · LIGHT-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • MULTI-SPAN 2 spans
  • SUPER-LED Superstructure-led
  • ARTERIAL-ADT Arterial ADT
  • LIGHT-LOAD Light load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: DEER PARK-MILAN RD

The DEER PARK-MILAN RD bridge in Spokane, Washington carries DEER PARK-MILAN RD over LITTLE SPOKANE RIVER. It was built in 1954, making it 72 years old today. The structure is built primarily of concrete and spans 2 sections, stretching 12.8 meters (42 feet) end to end. Daily traffic averages 2,046 vehicles, placing it in the moderately-trafficked tier of Washington bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed.

How DEER PARK-MILAN RD compares

▼ 17.7
Load rating vs Washington average (34.0 t; 8,455 of 8,474 rated)
307
Bridges in Spokane · 21 in Poor condition

Age against the county: built in 1954, earlier than 262 of Spokane's 307 bridges with a recorded construction year (85%), against a county median build year of 1973. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

DEER PARK-MILAN RD 16.3 t
Washington average (8,455 of 8,474 rated) 34.0 t

Live comparison across Washington bridges with a recorded inventory load rating (8,455 of 8,474 rated).

DEER PARK-MILAN RD vs every rated Washington bridge

Inventory load rating (metric tons), FHWA NBI, this state

16 Top 92% higher than 8% of 8,455 bridges

rated Washington bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
16.3 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Spokane inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 307 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1954
Material
Concrete
Number of Spans
2
Structure Length
12.8 m (42 ft)
Deck Width
8.3 m (27 ft)
Owner
County Highway Agency
Avg Daily Traffic
2,046 vehicles/day
Structure Number
084740000000000

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

DEER PARK-MILAN RD is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare DEER PARK-MILAN RD against other structures in Spokane and across Washington. Washington bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for DEER PARK-MILAN RD?

DEER PARK-MILAN RD in Spokane, Washington has a deck rating of 6/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is DEER PARK-MILAN RD inspected?

DEER PARK-MILAN RD's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,046 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. DEER PARK-MILAN RD is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for DEER PARK-MILAN RD?

DEER PARK-MILAN RD has an NBI inventory load rating of 16.3 metric tons.

Who is responsible for maintaining DEER PARK-MILAN RD?

DEER PARK-MILAN RD is owned and maintained by County Highway Agency.

How old is DEER PARK-MILAN RD and does age affect safety?

DEER PARK-MILAN RD was built in 1954, making it 72 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.