FHWA NBI 2024 Inspection record Public-domain dataset

MARION CO RT 80/2

Carrying MARION CO RT 80/2 over PRICKETT CREEK

0.03 MI WEST CO RT 80, Marion, West Virginia

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
24 t Inventory load rating Lower than 86% of rated West Virginia bridges

MARION CO RT 80/2 in Marion, West Virginia sits above 14% of rated West Virginia bridges on inventory load rating (24 t), while its 1949 build year is earlier than 80% of Marion's recorded-year cohort (193 bridges).

MARION CO RT 80/2 in Marion, West Virginia is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1949, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure WV:00000000025A153

PRE-1950 · STEEL · SINGLE-SPAN · DECK-LED · LOCAL-ADT · STANDARD-LOAD · CAT-POOR

  • PRE-1950 Pre-1950
  • STEEL Steel
  • SINGLE-SPAN Single span
  • DECK-LED Deck-led
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: MARION CO RT 80/2

The MARION CO RT 80/2 bridge in Marion, West Virginia carries MARION CO RT 80/2 over PRICKETT CREEK. It was built in 1949, making it 77 years old today. The structure is built primarily of steel and spans 1 section, stretching 16.6 meters (54 feet) end to end. Daily traffic averages 600 vehicles, placing it in the lower-traffic tier of West Virginia bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules.

How MARION CO RT 80/2 compares

▼ 17.0
Load rating vs West Virginia average (40.6 t; 7,347 of 7,348 rated)
193
Bridges in Marion · 41 in Poor condition

Age against the county: built in 1949, earlier than 155 of Marion's 193 bridges with a recorded construction year (80%), against a county median build year of 1988. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

MARION CO RT 80/2 23.6 t
West Virginia average (7,347 of 7,348 rated) 40.6 t

Live comparison across West Virginia bridges with a recorded inventory load rating (7,347 of 7,348 rated).

MARION CO RT 80/2 vs every rated West Virginia bridge

Inventory load rating (metric tons), FHWA NBI, this state

24 Top 86% higher than 14% of 7,347 bridges

rated West Virginia bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
23.6 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Marion inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 193 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1949
Material
Steel
Number of Spans
1
Structure Length
16.6 m (54 ft)
Deck Width
8.0 m (26 ft)
Owner
State Highway Agency
Avg Daily Traffic
600 vehicles/day
Structure Number
00000000025A153

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear on file for this vintage.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

MARION CO RT 80/2 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare MARION CO RT 80/2 against other structures in Marion and across West Virginia. West Virginia bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for MARION CO RT 80/2?

MARION CO RT 80/2 in Marion, West Virginia has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is MARION CO RT 80/2 inspected?

MARION CO RT 80/2's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 600 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. MARION CO RT 80/2 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for MARION CO RT 80/2?

MARION CO RT 80/2 has an NBI inventory load rating of 23.6 metric tons.

Who is responsible for maintaining MARION CO RT 80/2?

MARION CO RT 80/2 is owned and maintained by State Highway Agency.

How old is MARION CO RT 80/2 and does age affect safety?

MARION CO RT 80/2 was built in 1949, making it 77 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.