FHWA NBI 2024 Inspection record Public-domain dataset

30090 401st Avenue

Carrying 30090 401st Avenue over Choteau Creek

0.9S & 1.0E of Dante, Charles Mix, South Dakota

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
11 t Inventory load rating

Bridge Snapshot: 30090 401st Avenue

The 30090 401st Avenue bridge in Charles Mix, South Dakota carries 30090 401st Avenue over Choteau Creek. It was built in 1925, making it 101 years old today. It was last reconstructed in 1975, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 9.3 meters (31 feet) end to end. Daily traffic averages 48 vehicles, placing it in the lower-traffic tier of South Dakota bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 11.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How 30090 401st Avenue compares

▼ 21.4
Load rating vs South Dakota average (32.5 t)
Bottom 6%
Lower load rating than 94% of South Dakota bridges
103
Bridges in Charles Mix · 24 in Poor condition
30090 401st Avenue 11.1 t
South Dakota average 32.5 t

Live comparison across South Dakota.

Historical Sufficiency Rating

PlainBridge-computed
55.0 / 100 - historical 50–79.9 band
Structural adequacy /55
13.0
Serviceability /30
27.0
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
11.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1925
Last Reconstructed
1975
Material
Steel
Number of Spans
1
Structure Length
9.3 m (31 ft)
Deck Width
7.5 m (25 ft)
Owner
County Highway Agency
Avg Daily Traffic
48 vehicles/day
Structure Number
000000012570329

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether 30090 401st Avenue is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare 30090 401st Avenue against other structures in Charles Mix and across South Dakota. South Dakota bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 30090 401st Avenue?

30090 401st Avenue in Charles Mix, South Dakota has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is 30090 401st Avenue inspected?

30090 401st Avenue's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 48 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 30090 401st Avenue is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 30090 401st Avenue?

30090 401st Avenue has an NBI inventory load rating of 11.1 metric tons.

Who is responsible for maintaining 30090 401st Avenue?

30090 401st Avenue is owned and maintained by County Highway Agency.

How old is 30090 401st Avenue and does age affect safety?

30090 401st Avenue was built in 1925, making it 101 years old and last reconstructed in 1975.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.