FHWA NBI 2024 Inspection record Public-domain dataset

MAIN ST

Carrying MAIN ST over CANNONBALL RIVER

1 SOUTH OF NEW ENGLAND, Hettinger, North Dakota

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
5 t Inventory load rating

Bridge Snapshot: MAIN ST

The MAIN ST bridge in Hettinger, North Dakota carries MAIN ST over CANNONBALL RIVER. It was built in 1912, making it 114 years old today. The structure is built primarily of steel and spans 1 section, stretching 45.3 meters (149 feet) end to end. Daily traffic averages 50 vehicles, placing it in the lower-traffic tier of North Dakota bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 5.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How MAIN ST compares

▼ 27.2
Load rating vs North Dakota average (32.4 t)
Bottom 3%
Lower load rating than 97% of North Dakota bridges
64
Bridges in Hettinger · 10 in Poor condition
MAIN ST 5.2 t
North Dakota average 32.4 t

Live comparison across North Dakota.

Historical Sufficiency Rating

PlainBridge-computed
36.0 / 100 - historical 20–49.9 band
Structural adequacy /55
0.0
Serviceability /30
21.0
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
5.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1912
Material
Steel
Number of Spans
1
Structure Length
45.3 m (149 ft)
Deck Width
6.6 m (22 ft)
Owner
County Highway Agency
Avg Daily Traffic
50 vehicles/day
Structure Number
000000021103070

Condition Analysis

  • The deck (driving surface) is in poor condition (4/9), showing advanced deterioration that may require priority repair.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The substructure (piers and abutments) rates poor at 4/9, advanced deterioration that should be prioritized for repair.

How to read this record

MAIN ST is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare MAIN ST against other structures in Hettinger and across North Dakota. North Dakota bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for MAIN ST?

MAIN ST in Hettinger, North Dakota has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is MAIN ST inspected?

MAIN ST's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 50 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. MAIN ST is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for MAIN ST?

MAIN ST has an NBI inventory load rating of 5.2 metric tons.

Who is responsible for maintaining MAIN ST?

MAIN ST is owned and maintained by County Highway Agency.

How old is MAIN ST and does age affect safety?

MAIN ST was built in 1912, making it 114 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.