FHWA NBI 2024 Inspection record Public-domain dataset

SD028

Carrying SD028 over LAKE NORDEN OUTLET

1.5 E JCT SD 21 N, Hamlin, South Dakota

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
33 t Inventory load rating

Bridge Snapshot: SD028

The SD028 bridge in Hamlin, South Dakota carries SD028 over LAKE NORDEN OUTLET. It was built in 1949, making it 77 years old today. The structure is built primarily of concrete continuous and spans 3 sections, stretching 22.4 meters (73 feet) end to end. Daily traffic averages 2,060 vehicles, placing it in the moderately-trafficked tier of South Dakota bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 33.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SD028 compares

▲ 0.5
Load rating vs South Dakota average (32.5 t)
Top 35%
Higher load rating than 65% of South Dakota bridges
62
Bridges in Hamlin · 8 in Poor condition
SD028 33.0 t
South Dakota average 32.5 t

Live comparison across South Dakota.

Historical Sufficiency Rating

PlainBridge-computed
86.6 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
18.6
Essentiality /15
13.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
33.0 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1949
Material
Concrete Continuous
Number of Spans
3
Structure Length
22.4 m (73 ft)
Deck Width
10.5 m (34 ft)
Owner
State Highway Agency
Avg Daily Traffic
2,060 vehicles/day
Structure Number
000000029151149

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether SD028 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SD028 against other structures in Hamlin and across South Dakota. South Dakota bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SD028?

SD028 in Hamlin, South Dakota has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is SD028 inspected?

SD028's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,060 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SD028 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SD028?

SD028 has an NBI inventory load rating of 33.0 metric tons.

Who is responsible for maintaining SD028?

SD028 is owned and maintained by State Highway Agency.

How old is SD028 and does age affect safety?

SD028 was built in 1949, making it 77 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.