FHWA NBI 2024 Inspection record Public-domain dataset

SR 20

Carrying SR 20 over PUGET SND @ PT TOWNSEND

12.9 E JCT US 101, Jefferson, Washington

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
18 t Inventory load rating

Bridge Snapshot: SR 20

The SR 20 bridge in Jefferson, Washington carries SR 20 over PUGET SND @ PT TOWNSEND. It was built in 1955, making it 71 years old today. It was last reconstructed in 1982, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 27.4 meters (90 feet) end to end. Daily traffic averages 63 vehicles, placing it in the lower-traffic tier of Washington bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 4/9, substructure at 7/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 18.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SR 20 compares

▼ 15.4
Load rating vs Washington average (33.5 t)
Bottom 12%
Lower load rating than 88% of Washington bridges
100
Bridges in Jefferson · 4 in Poor condition
SR 20 18.1 t
Washington average 33.5 t

Live comparison across Washington.

Historical Sufficiency Rating

PlainBridge-computed
36.4 / 100 - historical 20–49.9 band
Structural adequacy /55
12.4
Serviceability /30
9.0
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
7/9
Good (7–9)
Inventory Load Rating
18.1 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1955
Last Reconstructed
1982
Material
Steel
Number of Spans
1
Structure Length
27.4 m (90 ft)
Deck Width
3.7 m (12 ft)
Owner
State Highway Agency
Avg Daily Traffic
63 vehicles/day
Structure Number
0012274B0000000

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear flagged for priority repair.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

SR 20 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SR 20 against other structures in Jefferson and across Washington. Washington bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 20?

SR 20 in Jefferson, Washington has a deck rating of 6/9, superstructure rating of 4/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SR 20 inspected?

SR 20's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 63 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 20 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 20?

SR 20 has an NBI inventory load rating of 18.1 metric tons.

Who is responsible for maintaining SR 20?

SR 20 is owned and maintained by State Highway Agency.

How old is SR 20 and does age affect safety?

SR 20 was built in 1955, making it 71 years old and last reconstructed in 1982.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.