FHWA NBI 2024 Inspection record Public-domain dataset

NFA A009

Carrying NFA A009 over POPLAR CREEK

NE OF SR61 AT MORGAN CO L, Anderson, Tennessee

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
32 t Inventory load rating

Bridge Snapshot: NFA A009

The NFA A009 bridge in Anderson, Tennessee carries NFA A009 over POPLAR CREEK. It was built in 1984, making it 42 years old today. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 31.1 meters (102 feet) end to end. Daily traffic averages 180 vehicles, placing it in the lower-traffic tier of Tennessee bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 32.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How NFA A009 compares

▲ 2.9
Load rating vs Tennessee average (29.5 t)
Bottom 39%
Lower load rating than 61% of Tennessee bridges
175
Bridges in Anderson · 6 in Poor condition
NFA A009 32.4 t
Tennessee average 29.5 t

Live comparison across Tennessee.

Historical Sufficiency Rating

PlainBridge-computed
78.4 / 100 - historical 50–79.9 band
Structural adequacy /55
55.0
Serviceability /30
10.5
Essentiality /15
14.9
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
32.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1984
Material
Prestressed Concrete
Number of Spans
3
Structure Length
31.1 m (102 ft)
Deck Width
7.2 m (24 ft)
Owner
County Highway Agency
Avg Daily Traffic
180 vehicles/day
Structure Number
010A0090001

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether NFA A009 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare NFA A009 against other structures in Anderson and across Tennessee. Tennessee bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for NFA A009?

NFA A009 in Anderson, Tennessee has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is NFA A009 inspected?

NFA A009's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 180 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. NFA A009 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for NFA A009?

NFA A009 has an NBI inventory load rating of 32.4 metric tons.

Who is responsible for maintaining NFA A009?

NFA A009 is owned and maintained by County Highway Agency.

How old is NFA A009 and does age affect safety?

NFA A009 was built in 1984, making it 42 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.