FHWA NBI 2024 Inspection record Public-domain dataset

MYERS RD

Carrying MYERS RD over UP RR

S 16 T 54 N R 29 W, Ray, Missouri

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
3 t Inventory load rating

Bridge Snapshot: MYERS RD

The MYERS RD bridge in Ray, Missouri carries MYERS RD over UP RR. It was built in 1940, making it 86 years old today. The structure is built primarily of steel and spans 1 section, stretching 40.2 meters (132 feet) end to end. Daily traffic averages 55 vehicles, placing it in the lower-traffic tier of Missouri bridges. It is owned and maintained by Railroad.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 6/9, substructure at 3/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 2.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How MYERS RD compares

▼ 31.0
Load rating vs Missouri average (33.7 t)
Bottom 1%
Lower load rating than 99% of Missouri bridges
185
Bridges in Ray · 23 in Poor condition
MYERS RD 2.7 t
Missouri average 33.7 t

Live comparison across Missouri.

Historical Sufficiency Rating

PlainBridge-computed
32.8 / 100 - historical 20–49.9 band
Structural adequacy /55
0.0
Serviceability /30
18.0
Essentiality /15
14.8
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
6/9
Fair (5–6)
Substructure
3/9
Poor (1–4)
Inventory Load Rating
2.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1940
Material
Steel
Number of Spans
1
Structure Length
40.2 m (132 ft)
Deck Width
6.4 m (21 ft)
Owner
Railroad
Avg Daily Traffic
55 vehicles/day
Structure Number
12681

Condition Analysis

  • The deck (driving surface) is in poor condition (4/9), showing advanced deterioration that may require priority repair.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) rates poor at 3/9, advanced deterioration that should be prioritized for repair.

How to read this record

MYERS RD is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare MYERS RD against other structures in Ray and across Missouri. Missouri bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for MYERS RD?

MYERS RD in Ray, Missouri has a deck rating of 4/9, superstructure rating of 6/9, and substructure rating of 3/9 on the FHWA's 0–9 scale.

How often is MYERS RD inspected?

MYERS RD's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 55 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. MYERS RD is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for MYERS RD?

MYERS RD has an NBI inventory load rating of 2.7 metric tons.

Who is responsible for maintaining MYERS RD?

MYERS RD is owned and maintained by Railroad.

How old is MYERS RD and does age affect safety?

MYERS RD was built in 1940, making it 86 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.