FHWA NBI 2024 Inspection record Public-domain dataset

WILL ROGERS TPI-44

Carrying WILL ROGERS TPI-44 over WHITE OAK CREEK O'FLOW

43.05 MI.NE OF TP GATE, Craig, Oklahoma

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
51 t Inventory load rating

Bridge Snapshot: WILL ROGERS TPI-44

The WILL ROGERS TPI-44 bridge in Craig, Oklahoma carries WILL ROGERS TPI-44 over WHITE OAK CREEK O'FLOW. It was built in 1957, making it 69 years old today. It was last reconstructed in 1992, extending its service life. The structure is built primarily of steel and spans 3 sections, stretching 39.0 meters (128 feet) end to end. Daily traffic averages 19,700 vehicles, placing it in the heavily-trafficked tier of Oklahoma bridges. It is owned and maintained by State Toll Authority.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 50.8 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How WILL ROGERS TPI-44 compares

▲ 18.4
Load rating vs Oklahoma average (32.4 t)
Top 9%
Higher load rating than 91% of Oklahoma bridges
176
Bridges in Craig · 32 in Poor condition
WILL ROGERS TPI-44 50.8 t
Oklahoma average 32.4 t

Live comparison across Oklahoma.

Historical Sufficiency Rating

PlainBridge-computed
91.0 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
25.0
Essentiality /15
11.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
50.8 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1957
Last Reconstructed
1992
Material
Steel
Number of Spans
3
Structure Length
39.0 m (128 ft)
Deck Width
22.8 m (75 ft)
Owner
State Toll Authority
Avg Daily Traffic
19,700 vehicles/day
Structure Number
138220000000000

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether WILL ROGERS TPI-44 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare WILL ROGERS TPI-44 against other structures in Craig and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for WILL ROGERS TPI-44?

WILL ROGERS TPI-44 in Craig, Oklahoma has a deck rating of 7/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is WILL ROGERS TPI-44 inspected?

WILL ROGERS TPI-44's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 19,700 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. WILL ROGERS TPI-44 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for WILL ROGERS TPI-44?

WILL ROGERS TPI-44 has an NBI inventory load rating of 50.8 metric tons.

Who is responsible for maintaining WILL ROGERS TPI-44?

WILL ROGERS TPI-44 is owned and maintained by State Toll Authority.

How old is WILL ROGERS TPI-44 and does age affect safety?

WILL ROGERS TPI-44 was built in 1957, making it 69 years old and last reconstructed in 1992.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.