FHWA NBI 2024 Inspection record Public-domain dataset

E1370

Carrying E1370 over CREEK

4.4 N; 0.6 W WISTER, Le Flore, Oklahoma

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
9 t Inventory load rating

Bridge Snapshot: E1370

The E1370 bridge in Le Flore, Oklahoma carries E1370 over CREEK. It was built in 1988, making it 38 years old today. The structure is built primarily of steel continuous and spans 2 sections, stretching 12.2 meters (40 feet) end to end. Daily traffic averages 175 vehicles, placing it in the lower-traffic tier of Oklahoma bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 9.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How E1370 compares

▼ 23.3
Load rating vs Oklahoma average (32.4 t)
Bottom 2%
Lower load rating than 98% of Oklahoma bridges
466
Bridges in Le Flore · 51 in Poor condition
E1370 9.1 t
Oklahoma average 32.4 t

Live comparison across Oklahoma.

Historical Sufficiency Rating

PlainBridge-computed
33.2 / 100 - historical 20–49.9 band
Structural adequacy /55
8.4
Serviceability /30
10.0
Essentiality /15
14.8
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
9.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1988
Material
Steel Continuous
Number of Spans
2
Structure Length
12.2 m (40 ft)
Deck Width
6.1 m (20 ft)
Owner
County Highway Agency
Avg Daily Traffic
175 vehicles/day
Structure Number
218820000000000

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 5/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether E1370 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare E1370 against other structures in Le Flore and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for E1370?

E1370 in Le Flore, Oklahoma has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is E1370 inspected?

E1370's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 175 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. E1370 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for E1370?

E1370 has an NBI inventory load rating of 9.1 metric tons.

Who is responsible for maintaining E1370?

E1370 is owned and maintained by County Highway Agency.

How old is E1370 and does age affect safety?

E1370 was built in 1988, making it 38 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.