FHWA NBI 2024 Inspection record Public-domain dataset

NFA A094

Carrying NFA A094 over SMALL BRANCH

0.5 MI SE JCT SR28&SR108, Marion, Tennessee

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
24 t Inventory load rating

Bridge Snapshot: NFA A094

The NFA A094 bridge in Marion, Tennessee carries NFA A094 over SMALL BRANCH. It was built in 1921, making it 105 years old today. The structure is built primarily of concrete and spans 1 section, stretching 9.4 meters (31 feet) end to end. Daily traffic averages 210 vehicles, placing it in the lower-traffic tier of Tennessee bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 5/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 24.3 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How NFA A094 compares

▼ 5.2
Load rating vs Tennessee average (29.5 t)
Bottom 14%
Lower load rating than 86% of Tennessee bridges
177
Bridges in Marion · 4 in Poor condition
NFA A094 24.3 t
Tennessee average 29.5 t

Live comparison across Tennessee.

Historical Sufficiency Rating

PlainBridge-computed
55.3 / 100 - historical 50–79.9 band
Structural adequacy /55
37.5
Serviceability /30
6.0
Essentiality /15
14.8
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
24.3 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1921
Material
Concrete
Number of Spans
1
Structure Length
9.4 m (31 ft)
Deck Width
6.4 m (21 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
210 vehicles/day
Structure Number
580A0940001

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether NFA A094 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare NFA A094 against other structures in Marion and across Tennessee. Tennessee bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for NFA A094?

NFA A094 in Marion, Tennessee has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is NFA A094 inspected?

NFA A094's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 210 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. NFA A094 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for NFA A094?

NFA A094 has an NBI inventory load rating of 24.3 metric tons.

Who is responsible for maintaining NFA A094?

NFA A094 is owned and maintained by City/Municipal Highway Agency.

How old is NFA A094 and does age affect safety?

NFA A094 was built in 1921, making it 105 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.