FHWA NBI 2024 Inspection record Public-domain dataset

NFA 921 (SA 6802)

Carrying NFA 921 (SA 6802) over BUFFALO RIVER

0.2 M. S. LINDEN., Perry, Tennessee

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
20 t Inventory load rating

Bridge Snapshot: NFA 921 (SA 6802)

The NFA 921 (SA 6802) bridge in Perry, Tennessee carries NFA 921 (SA 6802) over BUFFALO RIVER. It was built in 1958, making it 68 years old today. The structure is built primarily of concrete continuous and spans 3 sections, stretching 211.5 meters (694 feet) end to end. Daily traffic averages 1,475 vehicles, placing it in the moderately-trafficked tier of Tennessee bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 19.8 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How NFA 921 (SA 6802) compares

▼ 9.7
Load rating vs Tennessee average (29.5 t)
Bottom 7%
Lower load rating than 93% of Tennessee bridges
153
Bridges in Perry · 2 in Poor condition
NFA 921 (SA 6802) 19.8 t
Tennessee average 29.5 t

Live comparison across Tennessee.

Historical Sufficiency Rating

PlainBridge-computed
58.6 / 100 - historical 50–79.9 band
Structural adequacy /55
30.4
Serviceability /30
16.9
Essentiality /15
14.3
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
19.8 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1958
Material
Concrete Continuous
Number of Spans
3
Structure Length
211.5 m (694 ft)
Deck Width
10.5 m (34 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
1,475 vehicles/day
Structure Number
68F02430001

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear flagged for priority repair.
  • At 5/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

NFA 921 (SA 6802) is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare NFA 921 (SA 6802) against other structures in Perry and across Tennessee. Tennessee bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for NFA 921 (SA 6802)?

NFA 921 (SA 6802) in Perry, Tennessee has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is NFA 921 (SA 6802) inspected?

NFA 921 (SA 6802)'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,475 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. NFA 921 (SA 6802) is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for NFA 921 (SA 6802)?

NFA 921 (SA 6802) has an NBI inventory load rating of 19.8 metric tons.

Who is responsible for maintaining NFA 921 (SA 6802)?

NFA 921 (SA 6802) is owned and maintained by City/Municipal Highway Agency.

How old is NFA 921 (SA 6802) and does age affect safety?

NFA 921 (SA 6802) was built in 1958, making it 68 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.