FHWA NBI 2024 Inspection record Public-domain dataset

NFA A388 (SA 8410)

Carrying NFA A388 (SA 8410) over INDIAN CREEK CANAL

1.3 MI S OF BURLISON, Tipton, Tennessee

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
21 t Inventory load rating

Bridge Snapshot: NFA A388 (SA 8410)

The NFA A388 (SA 8410) bridge in Tipton, Tennessee carries NFA A388 (SA 8410) over INDIAN CREEK CANAL. It was built in 1965, making it 61 years old today. The structure is built primarily of prestressed concrete continuous and spans 3 sections, stretching 37.2 meters (122 feet) end to end. Daily traffic averages 1,130 vehicles, placing it in the moderately-trafficked tier of Tennessee bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 5/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 20.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How NFA A388 (SA 8410) compares

▼ 8.8
Load rating vs Tennessee average (29.5 t)
Bottom 8%
Lower load rating than 92% of Tennessee bridges
201
Bridges in Tipton · 9 in Poor condition
NFA A388 (SA 8410) 20.7 t
Tennessee average 29.5 t

Live comparison across Tennessee.

Historical Sufficiency Rating

PlainBridge-computed
54.9 / 100 - historical 50–79.9 band
Structural adequacy /55
32.0
Serviceability /30
12.0
Essentiality /15
13.9
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
20.7 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1965
Material
Prestressed Concrete Continuous
Number of Spans
3
Structure Length
37.2 m (122 ft)
Deck Width
8.7 m (29 ft)
Owner
County Highway Agency
Avg Daily Traffic
1,130 vehicles/day
Structure Number
840A3880001

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether NFA A388 (SA 8410) is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare NFA A388 (SA 8410) against other structures in Tipton and across Tennessee. Tennessee bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for NFA A388 (SA 8410)?

NFA A388 (SA 8410) in Tipton, Tennessee has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is NFA A388 (SA 8410) inspected?

NFA A388 (SA 8410)'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,130 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. NFA A388 (SA 8410) is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for NFA A388 (SA 8410)?

NFA A388 (SA 8410) has an NBI inventory load rating of 20.7 metric tons.

Who is responsible for maintaining NFA A388 (SA 8410)?

NFA A388 (SA 8410) is owned and maintained by County Highway Agency.

How old is NFA A388 (SA 8410) and does age affect safety?

NFA A388 (SA 8410) was built in 1965, making it 61 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.