FHWA NBI 2024 Inspection record Public-domain dataset

NFA 2569 (SA 9004)

Carrying NFA 2569 (SA 9004) over NOLICHUCKY RIVER

BTWN SR107 & US 11E, Washington, Tennessee

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
27 t Inventory load rating

Bridge Snapshot: NFA 2569 (SA 9004)

The NFA 2569 (SA 9004) bridge in Washington, Tennessee carries NFA 2569 (SA 9004) over NOLICHUCKY RIVER. It was built in 1958, making it 68 years old today. The structure is built primarily of concrete and spans 11 sections, stretching 125.4 meters (411 feet) end to end. Daily traffic averages 776 vehicles, placing it in the lower-traffic tier of Tennessee bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range. Its NBI inventory load rating is 26.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How NFA 2569 (SA 9004) compares

▼ 2.9
Load rating vs Tennessee average (29.5 t)
Bottom 29%
Lower load rating than 71% of Tennessee bridges
284
Bridges in Washington · 7 in Poor condition
NFA 2569 (SA 9004) 26.6 t
Tennessee average 29.5 t

Live comparison across Tennessee.

Historical Sufficiency Rating

PlainBridge-computed
77.5 / 100 - historical 50–79.9 band
Structural adequacy /55
50.5
Serviceability /30
13.0
Essentiality /15
14.1
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
26.6 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1958
Material
Concrete
Number of Spans
11
Structure Length
125.4 m (411 ft)
Deck Width
8.7 m (29 ft)
Owner
County Highway Agency
Avg Daily Traffic
776 vehicles/day
Structure Number
90025690003

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether NFA 2569 (SA 9004) is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare NFA 2569 (SA 9004) against other structures in Washington and across Tennessee. Tennessee bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for NFA 2569 (SA 9004)?

NFA 2569 (SA 9004) in Washington, Tennessee has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is NFA 2569 (SA 9004) inspected?

NFA 2569 (SA 9004)'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 776 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. NFA 2569 (SA 9004) is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for NFA 2569 (SA 9004)?

NFA 2569 (SA 9004) has an NBI inventory load rating of 26.6 metric tons.

Who is responsible for maintaining NFA 2569 (SA 9004)?

NFA 2569 (SA 9004) is owned and maintained by County Highway Agency.

How old is NFA 2569 (SA 9004) and does age affect safety?

NFA 2569 (SA 9004) was built in 1958, making it 68 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.