FHWA NBI 2024 Inspection record Public-domain dataset

NFA 815 (SA 9220)

Carrying NFA 815 (SA 9220) over OVERFLOW

4 MI E OF SR 43, Weakley, Tennessee

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
31 t Inventory load rating

Bridge Snapshot: NFA 815 (SA 9220)

The NFA 815 (SA 9220) bridge in Weakley, Tennessee carries NFA 815 (SA 9220) over OVERFLOW. It was built in 2004, making it 22 years old today. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 51.2 meters (168 feet) end to end. Daily traffic averages 272 vehicles, placing it in the lower-traffic tier of Tennessee bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 31.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How NFA 815 (SA 9220) compares

▲ 1.9
Load rating vs Tennessee average (29.5 t)
Bottom 37%
Lower load rating than 63% of Tennessee bridges
351
Bridges in Weakley · 4 in Poor condition
NFA 815 (SA 9220) 31.4 t
Tennessee average 29.5 t

Live comparison across Tennessee.

Historical Sufficiency Rating

PlainBridge-computed
98.7 / 100 - historical 80–100 band
Structural adequacy /55
54.7
Serviceability /30
29.2
Essentiality /15
14.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
31.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2004
Material
Prestressed Concrete
Number of Spans
3
Structure Length
51.2 m (168 ft)
Deck Width
9.2 m (30 ft)
Owner
County Highway Agency
Avg Daily Traffic
272 vehicles/day
Structure Number
92S80110003

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether NFA 815 (SA 9220) is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare NFA 815 (SA 9220) against other structures in Weakley and across Tennessee. Tennessee bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for NFA 815 (SA 9220)?

NFA 815 (SA 9220) in Weakley, Tennessee has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is NFA 815 (SA 9220) inspected?

NFA 815 (SA 9220)'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 272 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. NFA 815 (SA 9220) is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for NFA 815 (SA 9220)?

NFA 815 (SA 9220) has an NBI inventory load rating of 31.4 metric tons.

Who is responsible for maintaining NFA 815 (SA 9220)?

NFA 815 (SA 9220) is owned and maintained by County Highway Agency.

How old is NFA 815 (SA 9220) and does age affect safety?

NFA 815 (SA 9220) was built in 2004, making it 22 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.