FHWA NBI 2024 Inspection record Public-domain dataset

1080840-1.44

Carrying 1080840-1.44 over NO DATA ENTERED

SUEMEZ, Prince of Wales-Hyder, Alaska

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
20 t Inventory load rating Lower than 86% of rated Alaska bridges

1080840-1.44 in Prince of Wales-Hyder, Alaska sits above 14% of rated Alaska bridges on inventory load rating (20 t), while its 1992 build year is earlier than 39% of Prince of Wales-Hyder's recorded-year cohort (234 bridges).

1080840-1.44 in Prince of Wales-Hyder, Alaska is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1992, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure AK:100540000001062

LATE-CENTURY · STEEL · SINGLE-SPAN · TIED-CTRL · ADT-UNK · STANDARD-LOAD · CAT-FAIR

  • LATE-CENTURY 1980–1999
  • STEEL Steel
  • SINGLE-SPAN Single span
  • TIED-CTRL Tied control
  • ADT-UNK ADT unknown
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: 1080840-1.44

The 1080840-1.44 bridge in Prince of Wales-Hyder, Alaska carries 1080840-1.44 over NO DATA ENTERED. It was built in 1992, making it 34 years old today. It was last reconstructed in 2008, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 21.3 meters (70 feet) end to end. Average daily traffic is not reported for this structure. It is owned and maintained by U.S. Forest Service.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How 1080840-1.44 compares

▼ 18.1
Load rating vs Alaska average (38.2 t; 1,679 of 1,685 rated)
234
Bridges in Prince of Wales-Hyder · 16 in Poor condition

Age against the county: built in 1992, earlier than 92 of Prince of Wales-Hyder's 234 bridges with a recorded construction year (39%), against a county median build year of 1989. This is one of the newer structures in its county.

1080840-1.44 20.1 t
Alaska average (1,679 of 1,685 rated) 38.2 t

Live comparison across Alaska bridges with a recorded inventory load rating (1,679 of 1,685 rated).

1080840-1.44 vs every rated Alaska bridge

Inventory load rating (metric tons), FHWA NBI, this state

20 Top 86% higher than 14% of 1,679 bridges

rated Alaska bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
20.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Prince of Wales-Hyder inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 234 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1992
Last Reconstructed
2008
Material
Steel
Number of Spans
1
Structure Length
21.3 m (70 ft)
Deck Width
5.5 m (18 ft)
Owner
U.S. Forest Service
Structure Number
100540000001062

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether 1080840-1.44 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare 1080840-1.44 against other structures in Prince of Wales-Hyder and across Alaska. Alaska bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 1080840-1.44?

1080840-1.44 in Prince of Wales-Hyder, Alaska has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is 1080840-1.44 inspected?

1080840-1.44's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 1080840-1.44 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 1080840-1.44?

1080840-1.44 has an NBI inventory load rating of 20.1 metric tons.

Who is responsible for maintaining 1080840-1.44?

1080840-1.44 is owned and maintained by U.S. Forest Service.

How old is 1080840-1.44 and does age affect safety?

1080840-1.44 was built in 1992, making it 34 years old and last reconstructed in 2008.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.