FHWA NBI 2024 Inspection record Public-domain dataset

IRR BIA RTE 735

Carrying IRR BIA RTE 735 over SUKKWAN STRAIT

3.0 MILES EAST OF HYDABUR, Prince of Wales-Hyder, Alaska

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
0 t Inventory load rating Lower than 99% of rated Alaska bridges

IRR BIA RTE 735 in Prince of Wales-Hyder, Alaska sits above 1% of rated Alaska bridges on inventory load rating (0 t), while its 1970 build year is earlier than 98% of Prince of Wales-Hyder's recorded-year cohort (234 bridges).

IRR BIA RTE 735 in Prince of Wales-Hyder, Alaska is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1970, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure AK:E09211T0735-010

INTERSTATE-ERA · CONCRETE · LONG-SPAN-RUN · TIED-CTRL · TRACE-ADT · TRACE-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • CONCRETE Concrete
  • LONG-SPAN-RUN 7 spans
  • TIED-CTRL Tied control
  • TRACE-ADT Trace ADT
  • TRACE-LOAD Trace load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: IRR BIA RTE 735

The IRR BIA RTE 735 bridge in Prince of Wales-Hyder, Alaska carries IRR BIA RTE 735 over SUKKWAN STRAIT. It was built in 1970, making it 56 years old today. It was last reconstructed in 1981, extending its service life. The structure is built primarily of concrete and spans 7 sections, stretching 153.2 meters (503 feet) end to end. Daily traffic averages 5 vehicles, placing it in the lower-traffic tier of Alaska bridges. It is owned and maintained by Indian Tribal Government.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How IRR BIA RTE 735 compares

▼ 38.2
Load rating vs Alaska average (38.2 t; 1,679 of 1,685 rated)
234
Bridges in Prince of Wales-Hyder · 16 in Poor condition

Age against the county: built in 1970, earlier than 230 of Prince of Wales-Hyder's 234 bridges with a recorded construction year (98%), against a county median build year of 1989. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

IRR BIA RTE 735 0.0 t
Alaska average (1,679 of 1,685 rated) 38.2 t

Live comparison across Alaska bridges with a recorded inventory load rating (1,679 of 1,685 rated).

IRR BIA RTE 735 vs every rated Alaska bridge

Inventory load rating (metric tons), FHWA NBI, this state

0 Top 99% higher than 1% of 1,679 bridges

rated Alaska bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
0.0 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Prince of Wales-Hyder inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 234 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1970
Last Reconstructed
1981
Material
Concrete
Number of Spans
7
Structure Length
153.2 m (503 ft)
Deck Width
14.6 m (48 ft)
Owner
Indian Tribal Government
Avg Daily Traffic
5 vehicles/day
Structure Number
E09211T0735-010

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear on file for this vintage.
  • At 4/9, the substructure (piers and abutments) is in poor shape, with advanced wear on file for this vintage.

How to read this record

IRR BIA RTE 735 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare IRR BIA RTE 735 against other structures in Prince of Wales-Hyder and across Alaska. Alaska bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for IRR BIA RTE 735?

IRR BIA RTE 735 in Prince of Wales-Hyder, Alaska has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is IRR BIA RTE 735 inspected?

IRR BIA RTE 735's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. IRR BIA RTE 735 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for IRR BIA RTE 735?

IRR BIA RTE 735 has an NBI inventory load rating of 0.0 metric tons.

Who is responsible for maintaining IRR BIA RTE 735?

IRR BIA RTE 735 is owned and maintained by Indian Tribal Government.

How old is IRR BIA RTE 735 and does age affect safety?

IRR BIA RTE 735 was built in 1970, making it 56 years old and last reconstructed in 1981.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.