FHWA NBI 2024 Inspection record Public-domain dataset

US82 S5 LM 19.64WB

Carrying US82 S5 LM 19.64WB over SOUTHWEST AVE.

2.7 MI E JCT US 82 & 82B, Union, Arkansas

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Good
33 t Inventory load rating Higher than 63% of rated Arkansas bridges

US82 S5 LM 19.64WB in Union, Arkansas sits above 63% of rated Arkansas bridges on inventory load rating (33 t), while its 1979 build year is earlier than 71% of Union's recorded-year cohort (289 bridges).

US82 S5 LM 19.64WB in Union, Arkansas is rated Good in the FHWA's 2024 National Bridge Inventory. Built in 1979, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 7. The lowest applicable rating sets the federal condition category, so this Good result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure AR:0000000000B5788

INTERSTATE-ERA · STEEL · MULTI-SPAN · TIED-CTRL · ARTERIAL-ADT · STANDARD-LOAD · CAT-GOOD

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • MULTI-SPAN 3 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-GOOD Good

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: US82 S5 LM 19.64WB

The US82 S5 LM 19.64WB bridge in Union, Arkansas carries US82 S5 LM 19.64WB over SOUTHWEST AVE.. It was built in 1979, making it 47 years old today. The structure is built primarily of steel continuous and spans 3 sections, stretching 62.8 meters (206 feet) end to end. Daily traffic averages 4,860 vehicles, placing it in the moderately-trafficked tier of Arkansas bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range.

How US82 S5 LM 19.64WB compares

▲ 6.6
Load rating vs Arkansas average (26.1 t; 12,914 of 12,974 rated)
289
Bridges in Union · 3 in Poor condition

Age against the county: built in 1979, earlier than 204 of Union's 289 bridges with a recorded construction year (71%), against a county median build year of 2000. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

US82 S5 LM 19.64WB 32.7 t
Arkansas average (12,914 of 12,974 rated) 26.1 t

Live comparison across Arkansas bridges with a recorded inventory load rating (12,914 of 12,974 rated).

US82 S5 LM 19.64WB vs every rated Arkansas bridge

Inventory load rating (metric tons), FHWA NBI, this state

33 Top 37% higher than 63% of 12,914 bridges

rated Arkansas bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
32.7 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Union inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 289 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1979
Material
Steel Continuous
Number of Spans
3
Structure Length
62.8 m (206 ft)
Deck Width
13.1 m (43 ft)
Owner
State Highway Agency
Avg Daily Traffic
4,860 vehicles/day
Structure Number
0000000000B5788

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether US82 S5 LM 19.64WB is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare US82 S5 LM 19.64WB against other structures in Union and across Arkansas. Arkansas bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for US82 S5 LM 19.64WB?

US82 S5 LM 19.64WB in Union, Arkansas has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is US82 S5 LM 19.64WB inspected?

US82 S5 LM 19.64WB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 4,860 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. US82 S5 LM 19.64WB is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for US82 S5 LM 19.64WB?

US82 S5 LM 19.64WB has an NBI inventory load rating of 32.7 metric tons.

Who is responsible for maintaining US82 S5 LM 19.64WB?

US82 S5 LM 19.64WB is owned and maintained by State Highway Agency.

How old is US82 S5 LM 19.64WB and does age affect safety?

US82 S5 LM 19.64WB was built in 1979, making it 47 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.