FHWA NBI 2024 Inspection record Public-domain dataset

STC 3811;FH 61 RD.

Carrying STC 3811;FH 61 RD. over S.FK.BOISE RIVER

0.5S 0.4W FEATHERVILLE, Elmore, Idaho

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
25 t Inventory load rating Lower than 71% of rated Idaho bridges

STC 3811;FH 61 RD. in Elmore, Idaho sits above 29% of rated Idaho bridges on inventory load rating (25 t), while its 1968 build year is earlier than 64% of Elmore's recorded-year cohort (97 bridges).

STC 3811;FH 61 RD. in Elmore, Idaho is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1968, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure ID:000000000027875

INTERSTATE-ERA · PRESTRESS · MULTI-SPAN · TIED-CTRL · LOCAL-ADT · STANDARD-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 3 spans
  • TIED-CTRL Tied control
  • LOCAL-ADT Local ADT
  • STANDARD-LOAD Standard load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: STC 3811;FH 61 RD.

The STC 3811;FH 61 RD. bridge in Elmore, Idaho carries STC 3811;FH 61 RD. over S.FK.BOISE RIVER. It was built in 1968, making it 58 years old today. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 52.1 meters (171 feet) end to end. Daily traffic averages 580 vehicles, placing it in the lower-traffic tier of Idaho bridges. It is owned and maintained by Other Local Agencies.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range.

How STC 3811;FH 61 RD. compares

▼ 8.1
Load rating vs Idaho average (33.3 t; 4,574 of 4,616 rated)
97
Bridges in Elmore · 4 in Poor condition

Age against the county: built in 1968, earlier than 62 of Elmore's 97 bridges with a recorded construction year (64%), against a county median build year of 1973. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

STC 3811;FH 61 RD. 25.2 t
Idaho average (4,574 of 4,616 rated) 33.3 t

Live comparison across Idaho bridges with a recorded inventory load rating (4,574 of 4,616 rated).

STC 3811;FH 61 RD. vs every rated Idaho bridge

Inventory load rating (metric tons), FHWA NBI, this state

25 Top 71% higher than 29% of 4,574 bridges

rated Idaho bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
25.2 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Elmore inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 97 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1968
Material
Prestressed Concrete
Number of Spans
3
Structure Length
52.1 m (171 ft)
Deck Width
10.8 m (35 ft)
Owner
Other Local Agencies
Avg Daily Traffic
580 vehicles/day
Structure Number
000000000027875

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether STC 3811;FH 61 RD. is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare STC 3811;FH 61 RD. against other structures in Elmore and across Idaho. Idaho bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for STC 3811;FH 61 RD.?

STC 3811;FH 61 RD. in Elmore, Idaho has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is STC 3811;FH 61 RD. inspected?

STC 3811;FH 61 RD.'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 580 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. STC 3811;FH 61 RD. is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for STC 3811;FH 61 RD.?

STC 3811;FH 61 RD. has an NBI inventory load rating of 25.2 metric tons.

Who is responsible for maintaining STC 3811;FH 61 RD.?

STC 3811;FH 61 RD. is owned and maintained by Other Local Agencies.

How old is STC 3811;FH 61 RD. and does age affect safety?

STC 3811;FH 61 RD. was built in 1968, making it 58 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.