FHWA NBI 2024 Inspection record Public-domain dataset

N3080 (SANTA FE)

Carrying N3080 (SANTA FE) over LIGHTNING CREEK

.3N OF SW 44TH ST, Oklahoma, Oklahoma

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Poor
39 t Inventory load rating Higher than 79% of rated Oklahoma bridges

N3080 (SANTA FE) in Oklahoma, Oklahoma sits above 79% of rated Oklahoma bridges on inventory load rating (39 t), while its 1977 build year is earlier than 57% of Oklahoma's recorded-year cohort (1,216 bridges).

N3080 (SANTA FE) in Oklahoma, Oklahoma is rated Poor in the FHWA's 2024 National Bridge Inventory. Built in 1977, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 4. The lowest applicable rating sets the federal condition category, so this Poor result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure OK:193420000000000

INTERSTATE-ERA · PRESTRESS · MULTI-SPAN · TIED-CTRL · ARTERIAL-ADT · STANDARD-LOAD · CAT-POOR

  • INTERSTATE-ERA 1950–1979
  • PRESTRESS Prestressed concrete
  • MULTI-SPAN 2 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • STANDARD-LOAD Standard load
  • CAT-POOR Poor

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: N3080 (SANTA FE)

The N3080 (SANTA FE) bridge in Oklahoma, Oklahoma carries N3080 (SANTA FE) over LIGHTNING CREEK. It was built in 1977, making it 49 years old today. The structure is built primarily of prestressed concrete and spans 2 sections, stretching 38.7 meters (127 feet) end to end. Daily traffic averages 3,000 vehicles, placing it in the moderately-trafficked tier of Oklahoma bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 7/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order.

How N3080 (SANTA FE) compares

▲ 7.2
Load rating vs Oklahoma average (32.0 t; 22,909 of 22,917 rated)
1,216
Bridges in Oklahoma · 73 in Poor condition

Age against the county: built in 1977, earlier than 688 of Oklahoma's 1,216 bridges with a recorded construction year (57%), against a county median build year of 1982. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

N3080 (SANTA FE) 39.2 t
Oklahoma average (22,909 of 22,917 rated) 32.0 t

Live comparison across Oklahoma bridges with a recorded inventory load rating (22,909 of 22,917 rated).

N3080 (SANTA FE) vs every rated Oklahoma bridge

Inventory load rating (metric tons), FHWA NBI, this state

39 Top 21% higher than 79% of 22,909 bridges

rated Oklahoma bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
7/9
Good (7–9)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
39.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Oklahoma inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 1,216 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1977
Material
Prestressed Concrete
Number of Spans
2
Structure Length
38.7 m (127 ft)
Deck Width
10.4 m (34 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
3,000 vehicles/day
Structure Number
193420000000000

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear on file for this vintage.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) rates poor at 4/9, with advanced deterioration recorded on the latest inspection.

How to read this record

N3080 (SANTA FE) is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare N3080 (SANTA FE) against other structures in Oklahoma and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for N3080 (SANTA FE)?

N3080 (SANTA FE) in Oklahoma, Oklahoma has a deck rating of 4/9, superstructure rating of 7/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is N3080 (SANTA FE) inspected?

N3080 (SANTA FE)'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 3,000 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. N3080 (SANTA FE) is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for N3080 (SANTA FE)?

N3080 (SANTA FE) has an NBI inventory load rating of 39.2 metric tons.

Who is responsible for maintaining N3080 (SANTA FE)?

N3080 (SANTA FE) is owned and maintained by City/Municipal Highway Agency.

How old is N3080 (SANTA FE) and does age affect safety?

N3080 (SANTA FE) was built in 1977, making it 49 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.