FHWA NBI 2024 Inspection record Public-domain dataset

OR 126 (HWY 015)WB

Carrying OR 126 (HWY 015)WB over OR 99 (01W) NB & UPRR

00.2 MI W EUGENE ECL, Lane, Oregon

Inventory: FHWA NBI 2024 · last ETL August 2026

FHWA NBI record, refreshed with each annual release.

Fair
13 t Inventory load rating Lower than 95% of rated Oregon bridges

OR 126 (HWY 015)WB in Lane, Oregon sits above 5% of rated Oregon bridges on inventory load rating (13 t), while its 1961 build year is earlier than 73% of Lane's recorded-year cohort (1,010 bridges).

OR 126 (HWY 015)WB in Lane, Oregon is rated Fair in the FHWA's 2024 National Bridge Inventory. Built in 1961, it carries 3 rated components on the inspecting agency's 0-9 scale, and its weakest reported component scores 6. The lowest applicable rating sets the federal condition category, so this Fair result describes the weakest reported component rather than the structure as a whole. No NBI category is a closure decision or a live crossing-safety verdict.

NBI record plate

Structure OR:W6099C015 00009

INTERSTATE-ERA · STEEL · LONG-SPAN-RUN · TIED-CTRL · ARTERIAL-ADT · LIGHT-LOAD · CAT-FAIR

  • INTERSTATE-ERA 1950–1979
  • STEEL Steel
  • LONG-SPAN-RUN 5 spans
  • TIED-CTRL Tied control
  • ARTERIAL-ADT Arterial ADT
  • LIGHT-LOAD Light load
  • CAT-FAIR Fair

Inspection-sheet codes from this record’s year, material family, spans, controlling component, ADT, inventory load, and NBI category, not a live closure verdict.

Bridge Snapshot: OR 126 (HWY 015)WB

The OR 126 (HWY 015)WB bridge in Lane, Oregon carries OR 126 (HWY 015)WB over OR 99 (01W) NB & UPRR. It was built in 1961, making it 65 years old today. It was last reconstructed in 1979, extending its service life. The structure is built primarily of steel continuous and spans 5 sections, stretching 224.3 meters (736 feet) end to end. Daily traffic averages 6,950 vehicles, placing it in the moderately-trafficked tier of Oregon bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds.

How OR 126 (HWY 015)WB compares

▼ 18.8
Load rating vs Oregon average (31.8 t; 8,282 of 8,305 rated)
1,010
Bridges in Lane · 15 in Poor condition

Age against the county: built in 1961, earlier than 736 of Lane's 1,010 bridges with a recorded construction year (73%), against a county median build year of 1975. Age is not a defect on its own, but it is the population from which future Poor ratings are drawn.

OR 126 (HWY 015)WB 13.0 t
Oregon average (8,282 of 8,305 rated) 31.8 t

Live comparison across Oregon bridges with a recorded inventory load rating (8,282 of 8,305 rated).

OR 126 (HWY 015)WB vs every rated Oregon bridge

Inventory load rating (metric tons), FHWA NBI, this state

13 Top 95% higher than 5% of 8,282 bridges

rated Oregon bridges, bucketed by value

Each bar is a band; taller bars hold more bridges. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source FHWA National Bridge Inventory · August 2026

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
13.0 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Reported 0–9 component ratings from the FHWA NBI. The highlighted component is the lowest reported input to this record’s current condition category; it is not a closure or live crossing-safety decision.

Lane inventory by recorded NBI category

Exclusive Good/Fair/Poor bands across all 1,010 bridges in this county. Orthogonal to this structure's component profile above: a county catalog share, not a live crossing-safety verdict.

Structural Details

Year Built
1961
Last Reconstructed
1979
Material
Steel Continuous
Number of Spans
5
Structure Length
224.3 m (736 ft)
Deck Width
10.4 m (34 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
6,950 vehicles/day
Structure Number
W6099C015 00009

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether OR 126 (HWY 015)WB is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare OR 126 (HWY 015)WB against other structures in Lane and across Oregon. Oregon bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for OR 126 (HWY 015)WB?

OR 126 (HWY 015)WB in Lane, Oregon has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is OR 126 (HWY 015)WB inspected?

OR 126 (HWY 015)WB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,950 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. OR 126 (HWY 015)WB is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for OR 126 (HWY 015)WB?

OR 126 (HWY 015)WB has an NBI inventory load rating of 13.0 metric tons.

Who is responsible for maintaining OR 126 (HWY 015)WB?

OR 126 (HWY 015)WB is owned and maintained by City/Municipal Highway Agency.

How old is OR 126 (HWY 015)WB and does age affect safety?

OR 126 (HWY 015)WB was built in 1961, making it 65 years old and last reconstructed in 1979.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Share this inspection record

Send this source-bounded record or download its data card. An NBI condition category is not a closure or live crossing-safety verdict.

XFacebookLinkedInWhatsAppEmail

Every figure on PlainBridges is rendered directly from federal source data, no number is typed in by an editor. Component ratings, ADT, and condition category on this page are copied from the NBI record for this structure; no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error. Data current as of 2024 NBI release. NBI condition categories reflect the latest reported inventory record, not a live safety, closure, or travel decision.