FHWA NBI 2024 Inspection record Public-domain dataset

FAU 211

Carrying FAU 211 over BRANCH

2.4 M NE JCT SR3 &SR211, Dyer, Tennessee

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
28 t Inventory load rating

Bridge Snapshot: FAU 211

The FAU 211 bridge in Dyer, Tennessee carries FAU 211 over BRANCH. It was built in 1922, making it 104 years old today. It was last reconstructed in 1953, extending its service life. The structure is built primarily of concrete and spans 1 section, stretching 10.4 meters (34 feet) end to end. Daily traffic averages 5,117 vehicles, placing it in the moderately-trafficked tier of Tennessee bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 6/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 27.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How FAU 211 compares

▼ 1.6
Load rating vs Tennessee average (29.5 t)
Bottom 31%
Lower load rating than 69% of Tennessee bridges
232
Bridges in Dyer · 19 in Poor condition
FAU 211 27.9 t
Tennessee average 29.5 t

Live comparison across Tennessee.

Historical Sufficiency Rating

PlainBridge-computed
32.9 / 100 - historical 20–49.9 band
Structural adequacy /55
26.9
Serviceability /30
6.0
Essentiality /15
0.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
27.9 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1922
Last Reconstructed
1953
Material
Concrete
Number of Spans
1
Structure Length
10.4 m (34 ft)
Deck Width
10.5 m (34 ft)
Owner
State Highway Agency
Avg Daily Traffic
5,117 vehicles/day
Structure Number
23002270007

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

FAU 211 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare FAU 211 against other structures in Dyer and across Tennessee. Tennessee bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FAU 211?

FAU 211 in Dyer, Tennessee has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is FAU 211 inspected?

FAU 211's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5,117 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FAU 211 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FAU 211?

FAU 211 has an NBI inventory load rating of 27.9 metric tons.

Who is responsible for maintaining FAU 211?

FAU 211 is owned and maintained by State Highway Agency.

How old is FAU 211 and does age affect safety?

FAU 211 was built in 1922, making it 104 years old and last reconstructed in 1953.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.